Default how to caulk a diverter tub spout with a 1/4" gap with no backing

In my home I have a single piece shower / tub fiberglass unit...
something like...

http://www.lowes.com/lkn?action=prod...728-326032AL00

The problem is that the pipe for the diverter tub spout is not
perpendicular with the shower wall, and so when I screw on the spout, I
have about a 1/4" gap at the top of the spout, and the bottom of the
spout is flush with the fiberglass tub.

The spout looks like...

http://www.plumbingworld.com/images/als-1011-2010.jpg

Unfortunately, the spout is one of those cheap ones that is hollow
metal. And so there is only a sheet of metal at the top of the spout
that goes perpendicular to the shower wall, maybe 1/32" thick.

Also, for some reason there is a round sheet of plastic that goes
between the spout and the shower wall. Which creates yet another
complication for caulking. The plastic looks like it is to keep water
out of the hole in the fiberglass that the copper spout pipe goes
through.

[diverter tub spout][round plastic sheet][fiberglass shower wall]

Does anyone have any suggestion for how I can properly caulk this
spout?

My current plan is to:

1) tape the plastic sheet to the shower wall using blue tape.

2) caulk the gap with clear silicone (the gap has no backing because
the faucet is hollow)

3) let the caulk dry (maybe apply a second coat)

4) caulk around where the plastic sheet meets the shower wall

I have now begun to think that maybe I should glue the plastic sheet to
the shower wall, and then do (1), (2), (3), and (4).

Unfortunately this is a new home I purchased from a tract builder and
so I do not have any installation instructions for the tub/shower unit.

  #2   Report Post  
Colbyt
 
Posts: n/a
Default


"Jack" wrote in message
oups.com...
In my home I have a single piece shower / tub fiberglass unit...
something like...


http://www.lowes.com/lkn?action=prod...728-326032AL00

The problem is that the pipe for the diverter tub spout is not
perpendicular with the shower wall, and so when I screw on the spout, I
have about a 1/4" gap at the top of the spout, and the bottom of the
spout is flush with the fiberglass tub.

The spout looks like...

http://www.plumbingworld.com/images/als-1011-2010.jpg

Unfortunately, the spout is one of those cheap ones that is hollow
metal. And so there is only a sheet of metal at the top of the spout
that goes perpendicular to the shower wall, maybe 1/32" thick.

Also, for some reason there is a round sheet of plastic that goes
between the spout and the shower wall. Which creates yet another
complication for caulking. The plastic looks like it is to keep water
out of the hole in the fiberglass that the copper spout pipe goes
through.

[diverter tub spout][round plastic sheet][fiberglass shower wall]

Does anyone have any suggestion for how I can properly caulk this
spout?

My current plan is to:

1) tape the plastic sheet to the shower wall using blue tape.

2) caulk the gap with clear silicone (the gap has no backing because
the faucet is hollow)

3) let the caulk dry (maybe apply a second coat)

4) caulk around where the plastic sheet meets the shower wall

I have now begun to think that maybe I should glue the plastic sheet to
the shower wall, and then do (1), (2), (3), and (4).

Unfortunately this is a new home I purchased from a tract builder and
so I do not have any installation instructions for the tub/shower unit.


If this is a new home; why is this your problem to solve? Let the builder
take care of it.

That said and assuming you still need help; here is an off the cuff
solution. Spray some minimally expanding foam into the hollow spout through
the 1/4" gap, allow it to dry, trim off the excess and then caulk the darn
thing. No I have never done this or seen it done but it might work.


Colbyt


  #3   Report Post  
Jack
 
Posts: n/a
Default


If this is a new home; why is this your problem to solve? Let the

builder
take care of it.


It was a second bathtub/shower that we didn't use until after our 1
year warranty period. Honestly, I would scared to let this builder
back into my home to sweep a floor, let alone fix something they did
poorly to begin with.


That said and assuming you still need help; here is an off the cuff
solution. Spray some minimally expanding foam into the hollow spout

through
the 1/4" gap, allow it to dry, trim off the excess and then caulk the

darn
thing. No I have never done this or seen it done but it might work.


I was thinking about that.

I am also thinking that part of the problem is the big hole around the
copper pipe that goes through the fiberglass tub, and so I'm thinking
that there might be some standard way to seal that hole so that water
cannot flow thru it if the seal around the spout fails, but I'm still
not sure what to use to seal the hole (gaps): about a 1" gap around the
pipe. I've never used plumber's putty. Does anyone know what the
typical way is to eliminate these prefabricated gaps in fiberglass
tub/shower units?

  #4   Report Post  
Charles Bishop
 
Posts: n/a
Default

In article . com, "Jack"
wrote:


If this is a new home; why is this your problem to solve? Let the

builder
take care of it.


It was a second bathtub/shower that we didn't use until after our 1
year warranty period. Honestly, I would scared to let this builder
back into my home to sweep a floor, let alone fix something they did
poorly to begin with.


That said and assuming you still need help; here is an off the cuff
solution. Spray some minimally expanding foam into the hollow spout

through
the 1/4" gap, allow it to dry, trim off the excess and then caulk the

darn
thing. No I have never done this or seen it done but it might work.


I was thinking about that.

I am also thinking that part of the problem is the big hole around the
copper pipe that goes through the fiberglass tub, and so I'm thinking
that there might be some standard way to seal that hole so that water
cannot flow thru it if the seal around the spout fails, but I'm still
not sure what to use to seal the hole (gaps): about a 1" gap around the
pipe. I've never used plumber's putty. Does anyone know what the
typical way is to eliminate these prefabricated gaps in fiberglass
tub/shower units?


If possible get a flange that fits over the 1/2" copper pipe, probably
with a 3/4" or 1" hole for the fitting, and glue this in place on the tub.
The outside diameter will have to be smaller than the inside diameter of
your spout though, or you can make the flange part of the "design" if it's
chromed.

Cut off part of the copper pipe and add another piece to make it 1/4 to
3/8" longer. Then the tub spout will fit correctly. This would be best
since you don't want water getting behind the tub. This isn't that hard
since you won't be working on copper pipe that normally has water under
pressure in it.

Find anotheer spout that will seal to the tub with the 1/4" difference.
Not as easy, but different spouts can have different setbacks.

charles
  #5   Report Post  
Colbyt
 
Posts: n/a
Default


"Jack" wrote in message
ups.com...
I am also thinking that part of the problem is the big hole around the
copper pipe that goes through the fiberglass tub, and so I'm thinking
that there might be some standard way to seal that hole so that water
cannot flow thru it if the seal around the spout fails, but I'm still
not sure what to use to seal the hole (gaps): about a 1" gap around the
pipe. I've never used plumber's putty. Does anyone know what the
typical way is to eliminate these prefabricated gaps in fiberglass
tub/shower units?


There is no pre-drilled spout hole in a new tub. The installer drills the
hole. I usually drill a 3/4" hole for a 5/8" pipe. A bit of silicone seals
the rest.

But I have never had a problem with a spout not seating properly. Any gap
is usually at the bottom where it should be. Bet the butt hole ran straight
copper with no threaded connection between the faucet and the spout except
for the stub out. It should have a secured shower flange securely mounted
to a board inside the wall. The darn thing may twist off in your hands when
you try to replace it which someone will have to do someday.

BTW the is no limit on warranty in most states where a trades person does
something they know is improper.

Good luck.


Colbyt


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Screwfix Rainwater Diverter - it's 20mm diameter outlets Mungo Henning UK diy 0 July 1st 04 05:42 PM
Groaning TUB SPOUT ????? Conase Home Repair 2 December 16th 03 09:30 PM
Installing New Tub Spout andy Home Repair 4 October 19th 03 10:57 PM


All times are GMT +1. The time now is 08:13 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"