Pipe Dope
I grew up believing in pipe dope for all kinds of plumbing
connections - gas , liquid , etc . WHY IS IT then that when I use it to mount a cutoff valve on a PVC fitting it leaks virtually every time ? Just plumbed the claw foot tub and the cold has a seep on that fitting . And I'm out of teflon tape . -- Snag |
Pipe Dope
On Tuesday, May 23, 2017 at 8:00:17 PM UTC-5, Terry Coombs wrote:
I grew up believing in pipe dope for all kinds of plumbing connections - gas , liquid , etc . WHY IS IT then that when I use it to mount a cutoff valve on a PVC fitting it leaks virtually every time ? Just plumbed the claw foot tub and the cold has a seep on that fitting . And I'm out of teflon tape . -- Snag The pipe dope I recommend that I never had a problem using on any threaded pipe joint is made by RectorSeal. The local utilities use it too. ヽ(ヅ)ノ http://www.rectorseal.com/rectorseal-t-plus-2/ http://www.homedepot.com/p/RectorSea...3631/100201204 [8~{} Uncle Dopey Monster |
Pipe Dope
On 5/23/17 9:02 PM, Terry Coombs wrote:
I grew up believing in pipe dope for all kinds of plumbing connections - gas , liquid , etc . WHY IS IT then that when I use it to mount a cutoff valve on a PVC fitting it leaks virtually every time ? Just plumbed the claw foot tub and the cold has a seep on that fitting . And I'm out of teflon tape . -- Snag Mfr. Oatey says not to use Pipe Dope on plastic pipes. Use their product Hercules Real Tuff instead re Pipe Dope http://www.homedepot.com/catalog/pdf...9698cab43b.pdf "Do not use on threaded plastic pipes (use Hercules Real Tuff TM or Megaloc TM )." Re Real Tuff http://www.homedepot.com/catalog/pdf...37a8ac4e2d.pdf "use on Aluminum, Black Iron, Brass, Copper, Glass, Monel, Natural Rubber, Plastic(P.E.,Reinforced), PVC, ABS, CPVC" |
Pipe Dope
On Tue, 23 May 2017 18:22:04 -0700 (PDT), Uncle Monster wrote:
On Tuesday, May 23, 2017 at 8:00:17 PM UTC-5, Terry Coombs wrote: I grew up believing in pipe dope for all kinds of plumbing connections - gas , liquid , etc . WHY IS IT then that when I use it to mount a cutoff valve on a PVC fitting it leaks virtually every time ? Just plumbed the claw foot tub and the cold has a seep on that fitting . And I'm out of teflon tape . -- Snag The pipe dope I recommend that I never had a problem using on any threaded pipe joint is made by RectorSeal. The local utilities use it too. ?(?)? You misspelled "rectum." http://www.rectorseal.com/rectorseal-t-plus-2/ http://www.homedepot.com/p/RectorSea...3631/100201204 [8~{} Uncle Dopey Monster |
Pipe Dope
On Tuesday, May 23, 2017 at 8:52:29 PM UTC-5, Gordon Shumway wrote:
On Tue, 23 May 2017 18:22:04 -0700 (PDT), Uncle Monster wrote: On Tuesday, May 23, 2017 at 8:00:17 PM UTC-5, Terry Coombs wrote: I grew up believing in pipe dope for all kinds of plumbing connections - gas , liquid , etc . WHY IS IT then that when I use it to mount a cutoff valve on a PVC fitting it leaks virtually every time ? Just plumbed the claw foot tub and the cold has a seep on that fitting . And I'm out of teflon tape . -- Snag The pipe dope I recommend that I never had a problem using on any threaded pipe joint is made by RectorSeal. The local utilities use it too. ?(?)? You misspelled "rectum." I don't know why it's spelled that way, all I know is that it works on threaded pipe joints of all types. I've never tried it on my rectum though so I've no idea if it would stop it from leaking since it has no threads. Depend pull-ups do work quite well to contain leaks. ヽ(ヅ)ノ [8~{} Uncle Poopy Monster http://www.rectorseal.com/rectorseal-t-plus-2/ http://www.homedepot.com/p/RectorSea...3631/100201204 [8~{} Uncle Dopey Monster |
UNCLE MOBSTER TALKS ABOUT "Pipe Dope"
On 5/23/2017 6:22 PM, Uncle Monster wrote:
On Tuesday, May 23, 2017 at 8:00:17 PM UTC-5, Terry Coombs wrote: I grew up believing in pipe dope for all kinds of plumbing connections - gas , liquid , etc . WHY IS IT then that when I use it to mount a cutoff valve on a PVC fitting it leaks virtually every time ? The pipe dope I recommend that I never had a problem using on any threaded pipe joint is made by RectumSeal. Miss Recktum sure coulda used somma that stuff. She gots a leaky colostomy bag that leaks at the threads where it attaches to her ****-filled colon. Disgusting to say the least. |
Pipe Dope
On Tuesday, May 23, 2017 at 9:36:14 PM UTC-4, Retired wrote:
Mfr. Oatey says not to use Pipe Dope on plastic pipes. Use their product Hercules Real Tuff instead re Pipe Dope http://www.homedepot.com/catalog/pdf...9698cab43b.pdf "Do not use on threaded plastic pipes (use Hercules Real Tuff TM or Megaloc TM )." Re Real Tuff http://www.homedepot.com/catalog/pdf...37a8ac4e2d.pdf "use on Aluminum, Black Iron, Brass, Copper, Glass, Monel, Natural Rubber, Plastic(P.E.,Reinforced), PVC, ABS, CPVC" I've never used pipe dope on PVC, only on metal piping. PVC I aways use teflon tape. For me, it's just habit and what seemed right. Interesting that the dope manufacturer says not to use it on plastic. |