I am getting ready to finish the top section of a gambrel type roof on my
shed. I want to place a ridge vent across the top peak. All the pictures I
see of this type vent system shows the vent ending short of the edge of the
roof, and the sheeting being cut out where the vent will cover. Can I just
start laying the top sheeting 3" down from the peak and place the vent all
the way to the edge of the roof? This would let me use 3" less plywood on
each side of the roof sheeting, not have to cut it out after nailing it all
down. Is there a reason to not run the vent all the way over to the edge of
the roof line? Will it leak on the ends if installed this way? Does the roof
vent sections come with the ends capped off so they will not leak from the
ends?
Any information is appreciated. I will complete covering the top of the shed
roof this week. The shed is 12X20
Thanks in advance
C Cole

  #3   Report Post  
Randd01
 
Posts: n/a
Default Ridge Vent Instalation Question

If you use the honeycomb type ridge vents you can run them right the edge of
the roof and they will not leak. There in no special endcap just shouldered
nails so you dont drive them in too far. Home Depot sells this type of vent. I
have noticed a lot of new construction going to the edge of the roof with the
vent.
  #4   Report Post  
Rosen
 
Posts: n/a
Default Ridge Vent Instalation Question


"C Cole" wrote in message
I am getting ready to finish the top section of a gambrel type roof on my
shed. I want to place a ridge vent across the top peak. All the pictures I
see of this type vent system shows the vent ending short of the edge of

the
roof, and the sheeting being cut out where the vent will cover. Can I just
start laying the top sheeting 3" down from the peak and place the vent all
the way to the edge of the roof? This would let me use 3" less plywood on
each side of the roof sheeting, not have to cut it out after nailing it

all
down. Is there a reason to not run the vent all the way over to the edge

of
the roof line? Will it leak on the ends if installed this way? Does the

roof
vent sections come with the ends capped off so they will not leak from the
ends?
Any information is appreciated. I will complete covering the top of the

shed
roof this week. The shed is 12X20
Thanks in advance


3" down on each side? You're scaring me. That is way too much.

  #5   Report Post  
C Cole
 
Posts: n/a
Default Ridge Vent Instalation Question

Thanks to everyone for the replies,
I was given two links for ridge vents, one from Skil Tools and the other
from Owens-Corning. Both say I can run them to the edge and I am to have a 1
1/2" opening at the peak with trusses.
C Cole


"Rosen" wrote in message
...

"C Cole" wrote in message
I am getting ready to finish the top section of a gambrel type roof on

my
shed. I want to place a ridge vent across the top peak. All the pictures

I
see of this type vent system shows the vent ending short of the edge of

the
roof, and the sheeting being cut out where the vent will cover. Can I

just
start laying the top sheeting 3" down from the peak and place the vent

all
the way to the edge of the roof? This would let me use 3" less plywood

on
each side of the roof sheeting, not have to cut it out after nailing it

all
down. Is there a reason to not run the vent all the way over to the edge

of
the roof line? Will it leak on the ends if installed this way? Does the

roof
vent sections come with the ends capped off so they will not leak from

the
ends?
Any information is appreciated. I will complete covering the top of the

shed
roof this week. The shed is 12X20
Thanks in advance


3" down on each side? You're scaring me. That is way too much.




  #7   Report Post  
Michael Baugh
 
Posts: n/a
Default Ridge Vent Instalation Question


Yes, generally the vent space is an inch on both sides, and
you don't want to limit that by restricting the opening space
from the roof peak.

Jeff Cochran wrote in message
...
On 02 Nov 2003 17:15:47 GMT, (Randd01) wrote:

Yes one inch is more then enough!!!!!


He may be talking 3" total, or 1.5" on each side. Last ridge vent I
installed recommended a 1.5" opening on each side.

Jeff



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Simple question regarding Ceiling tiles and sound? lbbs UK diy 5 March 26th 04 02:36 AM
finishing ridge on traditional garage slate roof (except for manfactured trusses) Paul UK diy 0 January 14th 04 12:16 AM
Septic vent odor question Xeno Home Repair 8 July 20th 03 02:29 AM


All times are GMT +1. The time now is 09:45 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"