  #1   Report Post  
Alexander Galkin
 
Posts: n/a
Default Replacing cast iron DWV stack pipe

I need to replace large portion of main DWV stack. My main stack is composed
from two 4" cast iron Y fittings stacked one on another. There is then 4" by
3" cast iron reducer and then there is 3" copper stack pipe. All cast iron
fittings as well as main 3" copper stack pipe connected to cast iron reducer
are joined using bell end and lead. I need to remove all cast iron fittings
except one that enters my house from the street. I need then to cut 3"
copper stack pipe somewhere and replace all fittings and portion of copper
stack pipe with PVC pipe. I will use no-hub coupling to connect PVC pipe to
3" copper stack pipe. However how to connect PVC pipe to bell end of 4" cast
iron fitting that enters my house from the street? What's the proper way to
do this?


  #2   Report Post  
Speedy Jim
 
Posts: n/a
Default Replacing cast iron DWV stack pipe

Alexander Galkin wrote:

I need to replace large portion of main DWV stack. My main stack is composed
from two 4" cast iron Y fittings stacked one on another. There is then 4" by
3" cast iron reducer and then there is 3" copper stack pipe. All cast iron
fittings as well as main 3" copper stack pipe connected to cast iron reducer
are joined using bell end and lead. I need to remove all cast iron fittings
except one that enters my house from the street. I need then to cut 3"
copper stack pipe somewhere and replace all fittings and portion of copper
stack pipe with PVC pipe. I will use no-hub coupling to connect PVC pipe to
3" copper stack pipe. However how to connect PVC pipe to bell end of 4" cast
iron fitting that enters my house from the street? What's the proper way to
do this?


Consider the stronger Pro-Flex coupling for the PVC-to-Cu transition:
http://www.fernco.com/noframes/proflex.html

For entering the cast iron bell, use a rubber "Donut" (also Fernco).
Just slips in place; no lead req'd.

To remove the existing lead, use a long drill bit and
"swiss-cheese" the joint until you can pry the lead and oakum out.

Jim
  #3   Report Post  
Joe Bobst
 
Posts: n/a
Default Replacing cast iron DWV stack pipe

However how to connect PVC pipe to bell end of 4" cast
iron fitting that enters my house from the street? What's the proper way to do
this?

Check the Fernco fittings at your local box store, after making sure your
building code has approved them, of course. When you get the cast iron bell
ends free, measure the diameters. Much of the old CI stuff was pretty variable
in size and Fernco has oversizes for the inevitable surprises. Good luck.

Joe

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Replacing cast iron soil pipe Steve Loft UK diy 14 May 27th 04 11:59 PM
Wrought Iron, Cast Alum and Cast Iron Decorative welding Roy Metalworking 7 April 30th 04 09:52 AM
Bench Vise Questions (Steel vs. Iron) x Metalworking 2 September 1st 03 05:50 PM
Saniflow : Coupling copper pipe to soil stack Flat Eric UK diy 0 August 18th 03 02:20 PM
cutting a hole in a cast iron soil pipe Steve UK diy 7 August 11th 03 02:08 PM


All times are GMT +1. The time now is 05:42 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"