Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems.

 
 
LinkBack Thread Tools Search this Thread Display Modes
Prev Previous Post   Next Post Next
  #1   Report Post  
B
 
Posts: n/a
Default AC tripped at main breaker.....please advise

The outside compresser should keep the indoor coil cold, and if it wasn't
doing that, there's no damage done by blowing air across warm coil and
circulating it through your house. It could be bad to refrigerate the coil
and not blow air across it -- it might "freeze" and break. Just ask your
installer why the outdoor unit would be buzzing while the indoor unit
worked -- why they are not wired to know that the other is down (like I
think mine is).

"Kerry" wrote in message
om...
I am hoping you can all help me. Here is the story....

We live in a 1.5 year old house. Our AC coils our in our atic, then
we have the blower unit thing outdoors (sorry I don't know the real
names of these things).

We were away for the weekend and left the AC set at 85 degrees. It
was a hot weekend and the outside temp got up over 100 (probably
around 104). Anyway, when we returned home last night, our house was
a very warm 87 degrees. The fan was blowing but no cold air was
coming out. So I went outside and the outdoor portion of the AC unit
was not on. I put my ear up to it and could hear a faint electical
buzz. So it was getting power. Then I passed the condensation drain.
The ground was wet, so the AC had worked properly at least sometime
in the weekend. My next step was to go to the main breaker panel.
Sure enough, the AC was tripped. I reset and it is working fine so
far today.

A few questions....
1) What does the breaker control? The fan in the house was still
running and the unit outside still seemed to have power (since I could
hear the slight buzz). Does the breaker just control the coils?

2) What can cause the breaker to trip? And is that mean something
really bad is wrong?

3) The fact that it tripped concerns me. Is this something that
happens sometimes in really hot weather or is it more likely a problem
with my AC?

4) I have no idea how long the fan in my house had been running
before I came home. My guess is that it had been running for a long
time (many hours if not a whole day) trying to cool the house without
luck. Was that really bad for it? We let it rest overnight before we
tried it this morning.

Thanks all for the help. Out house is still under warranty, but since
it hasn't tripped again, I am not sure what to do. Please advise.

Kerry



 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
boiler / central heating problem - main burner weak and cuts out SledgehammerSteve UK diy 8 March 16th 04 12:32 PM
Should this have tripped the breaker? Ged UK diy 5 February 18th 04 07:52 PM
Help -- Power out in one area but circuit breaker not tripped Joseph Meehan Home Repair 0 June 27th 03 02:29 AM
breaker tripping barry martin Home Repair 0 June 23rd 03 08:58 PM


All times are GMT +1. The time now is 02:33 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"