DIYbanter

DIYbanter (https://www.diybanter.com/)
-   Home Repair (https://www.diybanter.com/home-repair/)
-   -   Air compressor hose size (https://www.diybanter.com/home-repair/293353-air-compressor-hose-size.html)

Ashton Crusher[_2_] December 5th 09 06:59 PM

Air compressor hose size
 
I've often wondered how much of the "energy" is getting lost thru
pressure drop in the hose from my air compressor to the tool. Plus
the thru hole in the fittings is pretty small. Yet none of the
regular outlets seems to carry any larger diameter hose or fittings. I
think the standard is around 1/4" or maybe 3/8. It' seems like a
larger hose would make tools that use a fair amount of air work a lot
better. Has anyone used larger hose and can offer a comparison?

Ed Pawlowski December 5th 09 09:37 PM

Air compressor hose size
 

"Ashton Crusher" wrote in message
...
I've often wondered how much of the "energy" is getting lost thru
pressure drop in the hose from my air compressor to the tool. Plus
the thru hole in the fittings is pretty small. Yet none of the
regular outlets seems to carry any larger diameter hose or fittings. I
think the standard is around 1/4" or maybe 3/8. It' seems like a
larger hose would make tools that use a fair amount of air work a lot
better. Has anyone used larger hose and can offer a comparison?


There are variables. Any restriction can cause a performance loss but a
1/4" diameter passage can carry quite a bit of air. In the case of impact
wrenches, nail guns, the amount fair per shot is minimal. Some spray guns,
sander, bead blasters can take considerably more cfm. In the case of a nail
gun, the pressure drop is negligible because of the recovery time between
hits, even on a fairly rapid pace. The larger the house or piping in the
system, the more reservoir you have , thus lessening the impact of the
orifice size at the point of use.



Jim December 5th 09 09:42 PM

Air compressor hose size
 

"Ashton Crusher" wrote in message
...
I've often wondered how much of the "energy" is getting lost thru
pressure drop in the hose from my air compressor to the tool. Plus
the thru hole in the fittings is pretty small. Yet none of the
regular outlets seems to carry any larger diameter hose or fittings. I
think the standard is around 1/4" or maybe 3/8. It' seems like a
larger hose would make tools that use a fair amount of air work a lot
better. Has anyone used larger hose and can offer a comparison?



See this link for a full explanation:

http://www.about-air-compressors.com/air-lines.html

Hope that'll help... Jim



Phisherman[_2_] December 5th 09 10:35 PM

Air compressor hose size
 
On Sat, 05 Dec 2009 11:59:46 -0700, Ashton Crusher
wrote:

I've often wondered how much of the "energy" is getting lost thru
pressure drop in the hose from my air compressor to the tool. Plus
the thru hole in the fittings is pretty small. Yet none of the
regular outlets seems to carry any larger diameter hose or fittings. I
think the standard is around 1/4" or maybe 3/8. It' seems like a
larger hose would make tools that use a fair amount of air work a lot
better. Has anyone used larger hose and can offer a comparison?


The material, length, amount of connectors, pressure, turbulence,
temperature, humidity, leaks(!) can greatly affect the volume and
"behavior" of delivered air. When using a blowgun short air spurts
are often better than one long slower blast. With a larger hose of
the same material the hose itself can store more energy--may be good
(or not) depending on your specific application/tool.

larry moe 'n curly December 5th 09 10:44 PM

Air compressor hose size
 


Ashton Crusher wrote:

I've often wondered how much of the "energy" is getting lost thru
pressure drop in the hose from my air compressor to the tool. Plus
the thru hole in the fittings is pretty small. Yet none of the
regular outlets seems to carry any larger diameter hose or fittings. I
think the standard is around 1/4" or maybe 3/8. It' seems like a
larger hose would make tools that use a fair amount of air work a lot
better. Has anyone used larger hose and can offer a comparison?


Graph showing pressure loss per 100 feet (loss is proportional to
lengty) for hoses from 1/4" to 1" diameter. Even going from 1/4" to
5/16" can help if the compressor is marginal:

http://adlersantiqueautos.com/images/compressed2.jpg




Ashton Crusher[_2_] December 5th 09 11:34 PM

Air compressor hose size
 
On Sat, 5 Dec 2009 15:42:57 -0600, "Jim" nospam@wherever wrote:


"Ashton Crusher" wrote in message
.. .
I've often wondered how much of the "energy" is getting lost thru
pressure drop in the hose from my air compressor to the tool. Plus
the thru hole in the fittings is pretty small. Yet none of the
regular outlets seems to carry any larger diameter hose or fittings. I
think the standard is around 1/4" or maybe 3/8. It' seems like a
larger hose would make tools that use a fair amount of air work a lot
better. Has anyone used larger hose and can offer a comparison?



See this link for a full explanation:

http://www.about-air-compressors.com/air-lines.html

Hope that'll help... Jim



Excellent. Looks like the drop isn't nearly as bad as I thought it
might be, perhaps 10 psi for my worst case.

Stormin Mormon December 5th 09 11:59 PM

Air compressor hose size
 
I have not done comparison. My best SWAG is that the
couplings are the big loss item. So, if possible, thread the
hoses together without the quick disconnect couplings.

From my fire department days, I know that water hoses
benefit greatly from larger sizes. I do try to buy larger
garden hoses for that reason.

--
Christopher A. Young
Learn more about Jesus
www.lds.org
..


"Ashton Crusher" wrote in message
...
I've often wondered how much of the "energy" is getting lost
thru
pressure drop in the hose from my air compressor to the
tool. Plus
the thru hole in the fittings is pretty small. Yet none of
the
regular outlets seems to carry any larger diameter hose or
fittings. I
think the standard is around 1/4" or maybe 3/8. It' seems
like a
larger hose would make tools that use a fair amount of air
work a lot
better. Has anyone used larger hose and can offer a
comparison?



Bob F December 6th 09 02:56 AM

Air compressor hose size
 
Stormin Mormon wrote:
I have not done comparison. My best SWAG is that the
couplings are the big loss item. So, if possible, thread the
hoses together without the quick disconnect couplings.

From my fire department days, I know that water hoses
benefit greatly from larger sizes. I do try to buy larger
garden hoses for that reason.


3/4" garden hoses make a big difference from 5/8" hoses. Especially if the
pressure is marginal.



Joe December 6th 09 11:52 PM

Air compressor hose size
 
On Dec 5, 12:59*pm, Ashton Crusher wrote:
I've often wondered how much of the "energy" is getting lost thru
pressure drop in the hose from my air compressor to the tool. *Plus
the thru hole in the fittings is pretty small. *Yet none of the
regular outlets seems to carry any larger diameter hose or fittings. I
think the standard is around 1/4" or maybe 3/8. * It' seems like a
larger hose would make tools that use a fair amount of air work a lot
better. *Has anyone used larger hose and can offer a comparison?


The answer is obvious. Always use 3/8" hose. Only one company makes
high flow fittings for the standard 1/4"NPT outlets on the hose and
that is MIlton. The ordinary box store fittings are M type, the Milton
high flow are the V type. The V type rate of flow is nearly double the
M type and I have been using them for a couple of years now for HVLP
spray guns and general shop use. Auto body supply stores carry Milton
stuff if you don't find it at your local Farm & Fleet.

Joe


All times are GMT +1. The time now is 02:34 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004 - 2014 DIYbanter