I have an central A/C condenser unit in the basement that is sweating
and water is dripping onto the floor. Will more insulation help?
Currently, I have turned off the A/C and just running the blower fan.
  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 944
Default condenser unit sweating

On Tue, 30 Jun 2009 16:22:00 -0400, Phisherman wrote:
I have an central A/C condenser unit in the basement that is sweating
and water is dripping onto the floor. Will more insulation help?
Currently, I have turned off the A/C and just running the blower fan.


It is normal for a condensor to gather water from the air. It'll have a drain
and that is where your problem lies.
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 3,236
Default condenser unit sweating

On Jun 30, 3:47*pm, AZ Nomad wrote:
On Tue, 30 Jun 2009 16:22:00 -0400, Phisherman wrote:
I have an central A/C condenser unit in the basement that is sweating
and water is dripping onto the floor. * Will more insulation help?
Currently, I have turned off the A/C and just running the blower fan.


It is normal for a condensor to gather water from the air. *It'll have a drain
and that is where your problem lies.


The condensor is outside, the evaporator is in the basement/
furnace!!!!!
  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 85
Default condenser unit sweating

On Jun 30, 5:03*pm, "hr(bob) "
wrote:
The condensor is outside, the evaporator is in the basement/
furnace!!!!!


Yes, and it's the evaporator, not the the condenser that gathers
water. (If the evaporator IS in the basement OR is sweating, he has
bigger problems.) As "AZ Nomad" said, there should be some sort of
drain that is probably clogged.

Phisherman, could you clarify what you mean by adding more insulation?


  #6   Report Post  
Posted to alt.home.repair
No Name
 
Posts: n/a
Default condenser unit sweating

I had one leaking a few years ago and the drain pan had rusted through
in a few places with the same result .. .. water ALL over the floor.
The guys at work fabricated one for me out of stainless .. .. THAT will
never leak !! !! !!

Phisherman wrote:
I have an central A/C condenser unit in the basement that is sweating
and water is dripping onto the floor. Will more insulation help?
Currently, I have turned off the A/C and just running the blower fan.


  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 232
Default condenser unit sweating

On Tue 30 Jun 2009 01:22:00p, Phisherman told us...

I have an central A/C condenser unit in the basement that is sweating
and water is dripping onto the floor. Will more insulation help?
Currently, I have turned off the A/C and just running the blower fan.


I doubt insulation is the issue. More likely the drain line from the drain
pan under the condenser is either clogged or the drain pan has deteriorated
and formed a leak.

If the former, the line is easily cleaned out. If the latter, depending on
the degree of deterioration, you may be able to repair it with liquid solder
or bondo. If the deterioration is extensive, you may need a new draiin pan.

FWIW, I once lived in a condo where the drain line clogged with some
frequency. I usually cleaned it out at least 2-3 times each cooling season.

HTH

--
Wayne Boatwright
------------------------------------------------------------------------
Red meat is not bad for you. Now blue ~green meat, that’s bad for
you! ~Tommy Smothers



  #8   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,375
Default condenser unit sweating

In article , Phisherman wrote:

My bad. It is the evaporator in the basement and located above the
furnace. There is a PVC drain, and I checked that there is water
flowing through the pipe to the outdoors. The outside of the
evaporator is cold, wet and dripping on all sides when the A/C is
turned on.


Too much humidity in the basement. Run a dehumidifier, or add a cold-air
return in the basement so that some of that humid air is sucked through the
evaporator and dehumdified.
  #9   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 11,538
Default condenser unit sweating

"__ Bøb __" wrote:
I had one leaking a few years ago and the drain pan had rusted through
in a few places with the same result .. .. water ALL over the floor.
The guys at work fabricated one for me out of stainless .. .. THAT
will never leak !! !! !!


Mine, too, gave it up. I got one of those PVC pans you put under washing
machines. Works swell and it'll last forever.


  #10   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 10,530
Default condenser unit sweating

If your condensor is sweatting, there is definitely
something wrong. You really need to call a HVAC pro.

--
Christopher A. Young
Learn more about Jesus
www.lds.org
..


"Phisherman" wrote in message
...
I have an central A/C condenser unit in the basement that is
sweating
and water is dripping onto the floor. Will more insulation
help?
Currently, I have turned off the A/C and just running the
blower fan.




  #11   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 10,530
Default condenser unit sweating

If your condensor is gathering water from the air, you need
to call a priest, immediately.

--
Christopher A. Young
Learn more about Jesus
www.lds.org
..


"AZ Nomad" wrote in message
...
On Tue, 30 Jun 2009 16:22:00 -0400, Phisherman
wrote:
I have an central A/C condenser unit in the basement that
is sweating
and water is dripping onto the floor. Will more
insulation help?
Currently, I have turned off the A/C and just running the
blower fan.


It is normal for a condensor to gather water from the air.
It'll have a drain
and that is where your problem lies.


  #12   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 10,530
Default condenser unit sweating

Hmm. What? Someone who knows something? How strange.

--
Christopher A. Young
Learn more about Jesus
www.lds.org
..


"hr(bob) " wrote in
message news:ece48041-7247-4ade-bdc1-

The condensor is outside, the evaporator is in the basement/
furnace!!!!!


  #13   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 10,530
Default condenser unit sweating

I've done that kind of thing.

--
Christopher A. Young
Learn more about Jesus
www.lds.org
..


"Doug Miller" wrote in message
...

add a cold-air
return in the basement so that some of that humid air is
sucked through the
evaporator and dehumdified.


  #14   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,597
Default condenser unit sweating

On Wed, 1 Jul 2009 22:09:55 -0400, "Stormin Mormon"
wrote:

If your condensor is gathering water from the air, you need
to call a priest, immediately.



To do an exorcism on my ac. But seriously, I put an insulation
foil-backed blanket around the evaporator housing this morning and
sealed all edges using foil tape. So far, everything is dry, no
sweating at all.
  #15   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 10,530
Default condenser unit sweating

Sounds totally effective. Way to go, chief!

--
Christopher A. Young
Learn more about Jesus
www.lds.org
..


"Phisherman" wrote in message
...

To do an exorcism on my ac. But seriously, I put an
insulation
foil-backed blanket around the evaporator housing this
morning and
sealed all edges using foil tape. So far, everything is
dry, no
sweating at all.


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Replacing Fan Motor - AC condenser unit Beowulf Home Repair 24 June 24th 15 09:28 AM
Found crack in cylindrical part inside A/C condenser unit JayN Home Repair 56 July 4th 08 03:57 AM
Cleaning compressor/condenser/outside unit Stormin Mormon Home Repair 12 September 5th 03 07:43 PM
Central air condenser unit failing? Walter Cohen Home Repair 2 July 15th 03 12:48 AM
Central air condenser unit failing? Walter Cohen Home Ownership 3 July 15th 03 12:48 AM


All times are GMT +1. The time now is 01:20 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"