Default Two questions about closed cell foam inuslation

I've heard about all the advantages, but:

1. Could it be so heavy that it jeopardizes the stability of the roof
in a roofline application?
2. The gas that it traps inside - I'm sure it slowly leaks over time -
what type of gas is it and is it dangerous?

Thanks in advance,

Aaron
  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,764
Default Two questions about closed cell foam inuslation

On Jun 22, 10:45*pm, Aaron Fude wrote:
I've heard about all the advantages, but:

1. Could it be so heavy that it jeopardizes the stability of the roof
in a roofline application?


Could it? If by that you mean "is it possible to add such a huge
weight of foam that it would jeopardize the structure." Yes. But
that is an extremely remote possibility. The stuff ain't free.

2. The gas that it traps inside - I'm sure it slowly leaks over time -
what type of gas is it and is it dangerous?


Are liquids poisonous? There are a number of different foams.
DAGS: closed cell foam off gassing

R

  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,926
Default Two questions about closed cell foam inuslation

On Jun 22, 9:45*pm, Aaron Fude wrote:
I've heard about all the advantages, but:

1. Could it be so heavy that it jeopardizes the stability of the roof
in a roofline application?
2. The gas that it traps inside - I'm sure it slowly leaks over time -
what type of gas is it and is it dangerous?

Thanks in advance,

Aaron


This is for a heated room underneath, right. Its very light it might
equal 1/2" of snow, I am guessing, my roof might take 2ft+ load no
problem. Some foams off gas little, some more, but the roof will
breath it out. In sun in a hot area the roof temp will go up, roof
life depending on type, may go down.
  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,764
Default Two questions about closed cell foam inuslation

On Jun 23, 11:31*am, Reno wrote:
Aaron Fude wrote in news:

I've heard about all the advantages, but:


1. Could it be so heavy that it jeopardizes the stability of the roof
in a roofline application?


The heaviest foams are about 2 lb per sq ft while roofs are supposed to be
designed for loads from 25 to over 50 lbs per sq ft. So the foam won't
overload your roof.


A square foot is an area, weights are measured by volume. You are
also making assumptions about the theoretical roof, such as that it
was properly designed to begin with, that there have been no
modifications (reroofing, truss chords cut), etc.

2. The gas that it traps inside - I'm sure it slowly leaks over time -
what type of gas is it and is it dangerous?


There are many different chemicals used for the foams but a good guess
would be that the foams could off-gas. These foams are used in many houses
so if you use one of the better known brands you would be safe. If this is
intended to be a living space you could get additional gas proofing by
using a vapor barrier over the foam. If it ia an open attis area then the
normal ventilation should prevent gas build up.


Polyethylene is the standard vapor barrier used in residential
construction. It is intended to drastically reduce water vapor
transmission, not gas transmission. I do not know the gas
permeability performance of polyethylene off hand, but it appears that
you are making another assumption.

R


  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 634
Default Two questions about closed cell foam inuslation

On 2009-06-23, Aaron Fude wrote:

1. Could it be so heavy that it jeopardizes the stability of the
roof in a roofline application?


Typical closed cell polyurethane foam insulation has a density around
2 lbs per cubic foot. [For exposed roof applications, where the foam
is the finished roof, the density can be higher.] So if you were to
spray it 6 inches deep, which is a lot of foam, that would be 1 lb per
square foot. By contrast, a typical design dead load would be 10 lbs
per square foot, and a design roof live load would be 20 lbs per
square foot, higher in areas with heavy snow.

2. The gas that it traps inside - I'm sure it slowly leaks over time -
what type of gas is it and is it dangerous?


The gas is called a blowing agent, you could try searching on that to
see what information you get. It does slowly leak out over time,
which is part of the reason there is some small degradation in R value
over time.

Cheers, Wayne

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Closed Cell Foam Insulation... BlinnPR Home Repair 3 January 10th 08 10:48 PM
Can I switch the sim in my damaged Cell Phone to a new Cell Phone? [email protected] Electronics Repair 3 September 30th 06 12:58 AM
Carpet Pad: Memory foam versus non-memory foam? [email protected] Home Repair 2 December 7th 05 04:15 AM
Decent cell phone headset & plug adaptation questions Dan Electronics Repair 4 January 21st 05 01:53 AM
Questions on weight-closed fencegate Dan Woodworking 13 July 25th 03 12:21 AM


All times are GMT +1. The time now is 11:53 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"