Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 2
Default Electric water heater - not enough hot water

I have a 14 year old electric water heater (40 gal, 2 4500w
elements). The water temp begins to cool down significantly in the
middle of a second shower. There are only 2 people in the house.

Thermostats work - both come on and off normally depending on how I
set them and they properly apply voltage to the heating elements.
Both heating elements show 15 ohms and draw 17+ amps.

Anybody got an idea what the problem could be?

TIA

Chuck
  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 8,803
Default Electric water heater - not enough hot water


wrote in message
...
I have a 14 year old electric water heater (40 gal, 2 4500w
elements). The water temp begins to cool down significantly in the
middle of a second shower. There are only 2 people in the house.

Thermostats work - both come on and off normally depending on how I
set them and they properly apply voltage to the heating elements.
Both heating elements show 15 ohms and draw 17+ amps.

Anybody got an idea what the problem could be?


Bad dip tube.


  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,563
Default Electric water heater - not enough hot water


wrote in message
...
I have a 14 year old electric water heater (40 gal, 2 4500w
elements). The water temp begins to cool down significantly in the
middle of a second shower. There are only 2 people in the house.

Thermostats work - both come on and off normally depending on how I
set them and they properly apply voltage to the heating elements.
Both heating elements show 15 ohms and draw 17+ amps.

Anybody got an idea what the problem could be?

TIA


I agree with Bob F, bad dip tube. The cold water is mixing at the top of the
tank with the hot water. With a 14 year old tank, I'd just replace it,
before the next thing goes

Chuck



  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 182
Default Electric water heater - not enough hot water

You may need to flush the deposits off the bottom of the tank. They not
only insulate the flame from the water and slow the recovery, but if they
are deep enough, they reduce the actual water capacity. I pulled (with a
coat hangar) a BUSS TUB full of deposits off the bottom of mine once upon a
time. Of course if you do this, be prepared to replace it. Mine started
leaking the next week after that.

s

they should be flushed at least a couple times a year.



wrote in message
...
I have a 14 year old electric water heater (40 gal, 2 4500w
elements). The water temp begins to cool down significantly in the
middle of a second shower. There are only 2 people in the house.

Thermostats work - both come on and off normally depending on how I
set them and they properly apply voltage to the heating elements.
Both heating elements show 15 ohms and draw 17+ amps.

Anybody got an idea what the problem could be?

TIA

Chuck





  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,563
Default Electric water heater - not enough hot water


"Steve Barker" wrote in message
...
You may need to flush the deposits off the bottom of the tank. They not
only insulate the flame from the water and slow the recovery, but if they
are deep enough, they reduce the actual water capacity. I pulled (with a
coat hangar) a BUSS TUB full of deposits off the bottom of mine once upon
a time. Of course if you do this, be prepared to replace it. Mine
started leaking the next week after that.

s

they should be flushed at least a couple times a year.



wrote in message
...
I have a 14 year old electric water heater (40 gal, 2 4500w
elements). The water temp begins to cool down significantly in the
middle of a second shower. There are only 2 people in the house.

Thermostats work - both come on and off normally depending on how I
set them and they properly apply voltage to the heating elements.
Both heating elements show 15 ohms and draw 17+ amps.

Anybody got an idea what the problem could be?

TIA

Chuck


How did you miss the part about it being electric



  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,926
Default Electric water heater - not enough hot water

On Jan 5, 1:17*pm, wrote:
I have a 14 year old electric water heater (40 gal, 2 4500w
elements). *The water temp begins to cool down significantly in the
middle of a second shower. *There are only 2 people in the house.

Thermostats work - both come on and off normally depending on how I
set them and they properly apply voltage to the heating elements.
Both heating elements show 15 ohms and draw 17+ amps.

Anybody got an idea what the problem could be?

TIA

Chuck


It wasnt like this last winter with the cold winter water temp and
everything else is equal, maybe a dip tube. 2 showers and cold
incomming water is a lot of immediate load on electric, was water temp
output as hot last winter.
  #8   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 182
Default Electric water heater - not enough hot water

i just noticed that when i re-read my reply. duh..

i guess they'd have to get REAL deep to get up over an electric element eh?
G

s


"RBM" wrote in message
...

How did you miss the part about it being electric





  #9   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 615
Default Electric water heater - not enough hot water

wrote:

Anybody got an idea what the problem could be?


Lower element burned out, or a dip tube that's dissolved/broken midway down.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Electric water heater - repalced everything still no hot water Mark Home Repair 4 September 19th 06 09:06 PM
Hot Water Heater: Gas vs. Electric Godzillarama Home Repair 8 April 15th 06 12:24 PM
Electric Water Heater Grounded to Copper Water Pipes? [email protected] Home Repair 4 October 30th 05 06:23 PM
electric water heater Ed Home Repair 4 December 7th 04 04:37 PM
electric water heater mmzz UK diy 4 January 6th 04 10:20 AM


All times are GMT +1. The time now is 01:04 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"