Default Electrical push connectors blow!

I finished wiring up my 3 way switches I asked about a while ago, but the
one switch only worked in one position. I assumed I had a common and
traveller reversed somewhere, but the wiring seemed fine. I finally pulled
both switches to check continuity and the same push connector was bad on
both switches, as well as a third switch I have for another circuit. I
changed to the screw connectors on both switches and all is beautiful now!

Thanks to Terry and RBM for the original help. I did end up cutting out the
entire ceiling betyween the two fixtures as you suggested. :-)



  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 3,469
Default Electrical push connectors blow!

On 4/12/2008 4:31 PM Bill Stock spake thus:

I finished wiring up my 3 way switches I asked about a while ago, but the
one switch only worked in one position. I assumed I had a common and
traveller reversed somewhere, but the wiring seemed fine. I finally pulled
both switches to check continuity and the same push connector was bad on
both switches, as well as a third switch I have for another circuit. I
changed to the screw connectors on both switches and all is beautiful now!

Thanks to Terry and RBM for the original help. I did end up cutting out the
entire ceiling betyween the two fixtures as you suggested. :-)


Note to self: Never use those stupid push connectors. That's what
[insert name of deity here] made the screw connectors for.


--
The best argument against democracy is a five-minute
conversation with the average voter.

- Attributed to Winston Churchill
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,746
Default Electrical push connectors blow!


David Nebenzahl wrote:

On 4/12/2008 4:31 PM Bill Stock spake thus:

I finished wiring up my 3 way switches I asked about a while ago, but the
one switch only worked in one position. I assumed I had a common and
traveller reversed somewhere, but the wiring seemed fine. I finally pulled
both switches to check continuity and the same push connector was bad on
both switches, as well as a third switch I have for another circuit. I
changed to the screw connectors on both switches and all is beautiful now!

Thanks to Terry and RBM for the original help. I did end up cutting out the
entire ceiling betyween the two fixtures as you suggested. :-)


Note to self: Never use those stupid push connectors. That's what
[insert name of deity here] made the screw connectors for.


The push connectors are terrible, but the screw clamped back wire
devices are really nice, particularly when using stranded wire. The only
seem to come on the "spec grade" devices and above.
  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,946
Default Electrical push connectors blow!

"Bill Stock" wrote in
:

I finished wiring up my 3 way switches I asked about a while ago, but
the one switch only worked in one position. I assumed I had a common
and traveller reversed somewhere, but the wiring seemed fine. I
finally pulled both switches to check continuity and the same push
connector was bad on both switches, as well as a third switch I have
for another circuit. I changed to the screw connectors on both
switches and all is beautiful now!

Thanks to Terry and RBM for the original help. I did end up cutting
out the entire ceiling betyween the two fixtures as you suggested. :-)





Guess you didn't mention you would be backstabbing it to hook it up. If
you did you would have got many one word replies - "Don't".

Someone please tell me why they even put that options on?! They are
notorious for failing as well as a fire and safety bombshell waiting to
go off, yet, code must allow it.
  #5   Report Post  
Posted to alt.home.repair
mm mm is offline
external usenet poster
 
Posts: 7,824
Default Electrical push connectors blow!

On Sat, 12 Apr 2008 17:22:45 -0700, David Nebenzahl
wrote:

On 4/12/2008 4:31 PM Bill Stock spake thus:

I finished wiring up my 3 way switches I asked about a while ago, but the
one switch only worked in one position. I assumed I had a common and
traveller reversed somewhere, but the wiring seemed fine. I finally pulled
both switches to check continuity and the same push connector was bad on
both switches, as well as a third switch I have for another circuit. I
changed to the screw connectors on both switches and all is beautiful now!

Thanks to Terry and RBM for the original help. I did end up cutting out the
entire ceiling betyween the two fixtures as you suggested. :-)


Note to self: Never use those stupid push connectors. That's what
[insert name of deity here] made the screw connectors for.


I think I used them when I made some changes when I first moved in. I
thought I was being modern. I think we're only talking about at most
5 receptacles and 2 switches, all in one room.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
using crimp-on electrical connectors rb Home Repair 17 June 30th 07 08:00 PM
weatherproof male/female connectors for electrical cable cqmman UK diy 2 April 10th 07 07:04 PM
Push in wire connectors Eigenvector Home Repair 30 December 13th 06 02:18 AM
Hozelock type male push-fit to compression hose connectors? Nigel Molesworth UK diy 11 June 20th 06 08:42 AM
Push fit connectors for central heating? Matthew UK diy 34 February 25th 06 01:59 PM


All times are GMT +1. The time now is 12:45 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"