I purchased a home last year and insisted on a comprehensive water
test. The test showed 3 items of concern, but my inspector insured me that those items were as a result of the water softener which he did not bypass to get a sample. I accepted those answers but am now not certain that they were accurate. In the last several months living here I have found the water to taste bad, poorly lather and leave a salty residue on washed dishes. I have had a (non-copper) pipe corrode and leak and a minor flood from a supply line nut corrododing away and coming free. To recheck the test results, and to make sure I am setting my softener correctly I brought a sample of water to my counter health dept that I bypassed the softener to get. I requested a hardness test and a corrosivity test and I am concerned by the results, the TDS in particular. LSI: -0.75 Alkalinity: 136 mg/l Hardness - Calcium: 208 mg/l Hardness - Total: 244 mg/l TDS: 1309 mg/l pH: 7.16 @ 17.7 pH Here is an excerpt of the ORIGINAL test results (it is 3 pages long in total with nearly a 100 items on it): No bacerial results Inorganic metals all ND or very low, except for Sodium at 640 mg/l Alkalinity: 120 mg/l Chloride: 520 mg/l Flouride: ND Hardness: ND -- ? Nitrate: 8.4 mg/l Nitrite: ND pH: 6.4 Sulfate: 30 TDS: 1300 mg/l I am considering getting my water tested again to identify what might be causing the high TDS. I am suspecting Chloride which the original test indicated and which I believe the inspector was mistaken to attribute to the softener as the softener exchanges Ca and Na but this should add chloride to the water. I am also thinking that this may be the consequence of a highway I live very near to in NY and de-icers penetrating the aquafier. I would very much appreciate some informed opinions and suggestions. I am not certain who I can contact to help me better interpret this data... the people I speak to seem to know considerably less than I do and I am not that well informed! Help! Michael |
#2
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
Michael wrote:
.... ... I brought a sample of water to my counter health dept that I bypassed the softener to get. I requested a hardness test and a corrosivity test and I am concerned by the results, the TDS in particular. LSI: -0.75 Alkalinity: 136 mg/l Hardness - Calcium: 208 mg/l Hardness - Total: 244 mg/l TDS: 1309 mg/l pH: 7.16 @ 17.7 pH Here is an excerpt of the ORIGINAL test results (it is 3 pages long in total with nearly a 100 items on it): No bacerial results Inorganic metals all ND or very low, except for Sodium at 640 mg/l Alkalinity: 120 mg/l Chloride: 520 mg/l Flouride: ND Hardness: ND -- ? Nitrate: 8.4 mg/l Nitrite: ND pH: 6.4 Sulfate: 30 TDS: 1300 mg/l I am considering getting my water tested again to identify what might be causing the high TDS. I am suspecting Chloride which the original test indicated and which I believe the inspector was mistaken to attribute to the softener as the softener exchanges Ca and Na but this should add chloride to the water. I am also thinking that this may be the consequence of a highway I live very near to in NY and de-icers penetrating the aquafier. I would very much appreciate some informed opinions and suggestions. I am not certain who I can contact to help me better interpret this data... the people I speak to seem to know considerably less than I do and I am not that well informed! Might start at http://www.health.state.ny.us/enviro...er_quality.htm There are additional links there as well... -- |
#3
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
Michael wrote:
I am considering getting my water tested again to identify what might be causing the high TDS. I am suspecting Chloride which the original test indicated and which I believe the inspector was mistaken to attribute to the softener as the softener exchanges Ca and Na but this should add chloride to the water. No, it adds sodium CaCO3 + NaCl yields NaCO3 + CaCl (which is what is flushed out doing regeneration, never enters your water) -- dadiOH ____________________________ dadiOH's dandies v3.06... ....a help file of info about MP3s, recording from LP/cassette and tips & tricks on this and that. Get it at http://mysite.verizon.net/xico |
#4
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On Apr 13, 6:38*am, "dadiOH" wrote:
Michael wrote: I am considering getting my water tested again to identify what might be causing the high TDS. *I am suspecting Chloride which the original test indicated and which I believe the inspector was mistaken to attribute to the softener as the softener exchanges Ca and Na but this should add chloride to the water. No, it adds sodium CaCO3 + NaCl yields NaCO3 + CaCl (which is what is flushed out doing regeneration, never enters your water) -- dadiOH ____________________________ dadiOH's dandies v3.06... ...a help file of info about MP3s, recording from LP/cassette and tips & tricks on this and that. Get it athttp://mysite.verizon.net/xico Sorry, I typoed and missed the word "not". I am suspecting Chloride which the original test indicated and which I believe the inspector was mistaken to attribute to the softener as the softener exchanges Ca and Na but this should --- NOT --- add chloride to the water. That was actually my point, the softener will add sodium to the water when it exchanges with the calcium, but this should NOT add chloride to my water. My inspector had told me my chloride results were high because of the softener... thank you for confirming my understanding to the contrary of what he told me. -Michael |
#5
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On Apr 13, 8:22 am, Michael wrote:
On Apr 13, 6:38 am, "dadiOH" wrote: Michael wrote: I am considering getting my water tested again to identify what might be causing the high TDS. I am suspecting Chloride which the original test indicated and which I believe the inspector was mistaken to attribute to thesofteneras thesoftenerexchanges Ca and Na but this should add chloride to the water. No, it adds sodium CaCO3 + NaCl yields NaCO3 + CaCl (which is what is flushed out doing regeneration, never enters your water) -- dadiOH ____________________________ dadiOH's dandies v3.06... ...a help file of info about MP3s, recording from LP/cassette and tips & tricks on this and that. Get it athttp://mysite.verizon.net/xico Sorry, I typoed and missed the word "not". I am suspecting Chloride which the original test indicated and which I believe the inspector was mistaken to attribute to thesofteneras thesoftenerexchanges Ca and Na but this should --- NOT --- add chloride to the water. That was actually my point, thesoftenerwill add sodium to the water when it exchanges with the calcium, but this should NOT add chloride to my water. My inspector had told me my chloride results were high because of thesoftener... thank you for confirming my understanding to the contrary of what he told me. -Michael The softener may not be working right and adding sodium and chloride to your water. Substitute potassium for sodium if you are using salt substitute instead of softener salt (sodium chloride). Yes road salting can cause high sodium, chlorides and TDS and all three are corrosive to metals. So get tests for pH (yours is a bit low), total hardness, TDS, chlorides, sodium, sulfates, iron, nitrate and Coliform bacteria. Your nitrate is somewhat high and that can be a health concern, especially for a fetus and infants. Nitrate fluctuates seasonally with precipitation levels and snow melt. The Langelier Saturation Index (LSI) is not a good corrosivity test, there are others that are much better but IMO none will benefit you much in identifying what might be causing corrosion and we know that high TDS, chloride and sodium will cause it. Gary Slusser Quality Water Associates |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Which? Boiler test results | UK diy | |||
Hot Water Heater Draw Test Results? | Home Repair | |||
Well Water Test Results and Questions... | Home Ownership | |||
Well Water Test Results and Questions... | Home Repair | |||
Pool GFI Revisited - test results! Pipedown? | Home Repair |