Putting in a basement appartment. I want to run 4" ducting up inside a 2x4
wall, up past the 8 foot concrete wall and outside between the floor joist.

Can I bend or squat the 4" to fit in the wall? I guess I could cut out some
of the 2" polystyrene insulation 1/2 and inch to fit.

Steve


  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,934
Default Venting for dryer Vent


"SteveC" wrote in message
...
Putting in a basement appartment. I want to run 4" ducting up inside a
2x4 wall, up past the 8 foot concrete wall and outside between the floor
joist.

Can I bend or squat the 4" to fit in the wall? I guess I could cut out
some of the 2" polystyrene insulation 1/2 and inch to fit.



Restricting the duct could affect the dryer's performance. If going up
inside of the wall is your only option, then I suggest using oval duct. It
will have a larger capacity than the 4" round and is made to fit into walls.
You may have to get some transitions from oval to 4" round fabricated to put
on each end. Any sheet metal shop can do this.

  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 205
Default Venting for dryer Vent

SteveC wrote:
Putting in a basement appartment. I want to run 4" ducting up inside a 2x4
wall, up past the 8 foot concrete wall and outside between the floor joist.

Can I bend or squat the 4" to fit in the wall? I guess I could cut out some
of the 2" polystyrene insulation 1/2 and inch to fit.

Steve



http://www.deflecto.com/OMS/tier1_te...CategoryID=903
may have what you want.

You would not want any combustible insulation
in the space at all and clearance must be
maintained to the studs/walls.

If the basement apt will be requiring a permit,
ask about the venting requirements at the bldg dep't first.

Jim
  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 14
Default Venting for dryer Vent

On Feb 29, 6:32*am, "SteveC" wrote:
Putting in a basement appartment. *I want to run 4" ducting up inside a 2x4
wall, up past the 8 foot concrete wall and outside between the floor joist..

Can I bend or squat the 4" to fit in the wall? *I guess I could cut out some
of the 2" polystyrene insulation 1/2 and inch to fit.

Steve


It is better to run the ducting outside the wall. That's the only way
I've ever seen it done and there are several good reasons I can think
of. 1. The insulation of what is presumable an exterior wall will be
compromised far less. 2. It will be easier to access or service ithe
ducting n the future should the need arise. 3. That vent will get
hot and could be a fire hazard if placed inside a wall.

I know it sounds neat to hide the vent inside the wall but I do not
see it as a good idea
  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 15
Default Venting for dryer Vent

On Feb 29, 7:32 am, "SteveC" wrote:
Putting in a basement appartment. I want to run 4" ducting up inside a 2x4
wall, up past the 8 foot concrete wall and outside between the floor joist.

Can I bend or squat the 4" to fit in the wall? I guess I could cut out some
of the 2" polystyrene insulation 1/2 and inch to fit.

Steve


Steve:

You must have a duct with the same cross-section area as the 4in duct.
Since a 4in duct has a cross -section of about 13 sqin, you must have
a rectangular duct of at least that cross section.

I have done what you are trying to do; installed a dryer on the second
floor and moved the vent up a wall, into the attic and to the top of
the roof. Total linear footage is about 12 feet, vertically, with only
one bend, the 90 degree between the dryer and the wall. My 4in duct
goes into a rectangular 3inx10in heating duct, and then connects at
the roof with a 4in discharge vent. I thought that I might have a
problem with the velocity of the discharge (since the area in the
rectangular duct is much larger than the area of the 4in duct), and I
have checked periodically to see whether lint accumulated at the
bottom of the rectangular duct, and none is present. That's been seven
years since I moved our laundry room to the second floor. I have had
no problem whatever. FWIW, it's a Maytag Neptune gas dryer.

Yes, I have a pan connected to a drain under the washer. Thanks.

Pierre


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Venting bathroom fan to ridge vent - is it ok? Bill Christens-Barry Home Repair 15 April 21st 19 10:15 PM
Range hood vent options/ self venting or vent through roof ? Mikepier Home Repair 3 September 3rd 07 07:48 AM
Venting bathroom fan through the ridge vent Mike Shapp Home Repair 3 November 18th 06 07:46 PM
new Maytag dryer clogs dryer vent shedmeister Home Ownership 2 January 10th 05 10:40 PM


All times are GMT +1. The time now is 08:28 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"