Island Vent - Distance Limit
I have a old, thin-walled house with external galvanized iron dwv
servicing the kitchen sink and dish washer. The dwv is rusting through in spots and needs to be replaced. The nearest location in the house where a vent pipe can be run internally to the roof is at the utility room ~30' away. The other option is to run another external dwv pipe. If I were to put in a island vent under the sink, is 30' too far of a horizontal run for the foot vent? If that's not an option, what do people generally use for external dwv now?, abs, pvc? |
#2
Posted to alt.home.repair
|
|||
|
|||
Island Vent - Distance Limit
localhost wrote:
I have a old, thin-walled house with external galvanized iron dwv servicing the kitchen sink and dish washer. The dwv is rusting through in spots and needs to be replaced. The nearest location in the house where a vent pipe can be run internally to the roof is at the utility room ~30' away. The other option is to run another external dwv pipe. If I were to put in a island vent under the sink, is 30' too far of a horizontal run for the foot vent? If that's not an option, what do people generally use for external dwv now?, abs, pvc? Obviously, the local inspector is the person with hard answers and interpretations. You can run ABS or painted PVC or even copper for the outside vent. It's not DWV, but electrical conduit will hold up well too. 30 Ft is not too far for one fixture on a 1 1/2" vent. Remember, it has to slope upward toward the vent stack though. Nothing too exciting he http://www.theplumber.com/vent.html http://tinyurl.com/33f64c Jim |
#3
Posted to alt.home.repair
|
|||
|
|||
Island Vent - Distance Limit
On Feb 5, 2:49�pm, Speedy Jim wrote:
localhost wrote: I have a old, thin-walled house with external galvanized iron dwv servicing the kitchen sink and dish washer. The dwv is rusting through in spots and needs to be replaced. The nearest location in the house where a vent pipe can be run internally to the roof is at the utility room ~30' away. The other option is to run another external dwv pipe. If I were to put in a island vent under the sink, is 30' too far of a horizontal run for the foot vent? If that's not an option, what do people generally use for external dwv now?, abs, pvc? Obviously, the local inspector is the person with hard answers and interpretations. You can run ABS or painted PVC or even copper for the outside vent. It's not DWV, but electrical conduit will hold up well too. 30 Ft is not too far for one fixture on a 1 1/2" vent. �Remember, it has to slope upward toward the vent stack though. Nothing too exciting hehttp://www.theplumber.com/vent.htmlh...url.com/33f64c Jim I wasa under the impressions islands could use those mini vents? or whats known as a loop vent |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Range hood vent options/ self venting or vent through roof ? | Home Repair | |||
DRYER HI LIMIT THERMOSTAT SHUTS OFF==NOT A VENT PROBLEM | Home Repair | |||
Power Vent on Direct Vent Water Heater | Home Repair | |||
Plumbing Vent for Kitchen Island | Home Repair |