The most important thing to remember when buying tubing is that the
inside diameter must not be greater than the outside diameter, otherwise the hole will be on the outside of the pipe. Seriously though, I have stuck 5/8 ref (1/2 plumbing) copper into 3/4 ref. tubing and soldered the joint with no problem at all. Also put 7/8 ref (3/4 pl) over 3/4 ref and done the same thing. It is done all the time in A/C. About a year ago we had an idiot helper slice through a 1/2" water line(what we call 5/8) with a sawzall. He mangled up about 4-6 " of the pipe. and besides being nearly impossible to get to (I was the only one who could squeeze into the space) the pipe would not move at all in any direction. I just cut a piece of 3/4 ref about 4" longer than the gap in the line, managed to get it on like a giant repair coupling, and soldered it up. Worked fine. HOWEVER, I only use silver solder on copper tubing regardless of it's use, so ymmv using soft solder, but the tubing fits into the larger one tightly, so there should not really be any/much difference between that and using a coupling or other fitting. Good luck Larry |