We are having a problem with fireplace in our new-ish doublewide that we
erected for a cabin. The fireplace has a fresh air intake which comes up
through the floor into the firebox. Unfortunately, it isn't enough and we
get smoke in the house - not enough to set off the smoke detector in the
same room but it sure makes our eyes burn. Investigating the paperwork with
the unit states that when this unit is installed in an air-tight,
manufactured home it 'may' be necessary to open a window for adequate draft.
I'm thinking that I should be able to install a duct fan in the draft duct
to keep from opening the window. Is this a good idea or do you see a
problem with controlling the burn rate in the firebox?
TIA
Chuck


  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 627
Default Improving fireplace draft

Make sure the chimney is not obstructed. Also that the air vent to the
outside is not obstructed.

Sometimes a screen spark guard on the top of a chimney will clog. It may
look fine from below, but get up on roof and you will see that it is clogged
so little or no smoke can get out the chimney. I removed my spark guard
because it was always clogging.

Also if the air vent opening is coming from the crawlspace under your home,
be sure there is an opening to the crawl space to allow air to flow into the
crawlspace, then into the vent. Or it may just be a hose like a dryer vent
hose going to the outside? In any case, be sure air can flow into the air
vent.

Then if there is a "valve" or "damper" on the intake air, be sure it is open
all the way.

Then once all that is checked, the chimney needs to get hot first so you
will get a draft. Crack a door or window inside your house, then build your
fire, then leave door to fireplace open a bit. This will allow the heat to
go up and heat up the chimney. After a few minutes the chimney will heat up,
then you can close the door to the fireplace and the door in your house.

When first heating up my chimney, I like to add some paper to the fire so it
gets hot right away.

If the chimney is not hot and you close the door to the fireplace, the smoke
will just hang around inside and the fire will go out.

To build a fire, I put down paper, then a firestarter, then some thin dry
kindling wood, then 3 pieces of firewood. The pieces of wood on the bottom
have a gap of about 3 inches between them. Then the third piece covers this
gap on top. The firestarter and kindling is below this gap.

So I have built a little "room" inside the fireplace for the fire to get
started.

One piece of wood will start to burn and this heats up the opposite piece of
wood. And the "roof" piece keeps the heat in the 3 inch gap. So it can get
hot real quick inside that little "room". Then this in turn heats up the
rest of the fireplace and then the outside portions of the wood will begin
to burn.

Wood will not just burn if you hold a match to it. It burns best if it is
hot inside the fireplace. Sort of hard to get started.




"C & E" wrote in message
We are having a problem with fireplace in our new-ish doublewide that we
erected for a cabin. The fireplace has a fresh air intake which comes up
through the floor into the firebox. Unfortunately, it isn't enough and we
get smoke in the house - not enough to set off the smoke detector in the
same room but it sure makes our eyes burn. Investigating the paperwork
with the unit states that when this unit is installed in an air-tight,
manufactured home it 'may' be necessary to open a window for adequate
draft. I'm thinking that I should be able to install a duct fan in the
draft duct to keep from opening the window. Is this a good idea or do you
see a problem with controlling the burn rate in the firebox?
TIA
Chuck



  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 53
Default Improving fireplace draft

"Bill" wrote in message
...
Make sure the chimney is not obstructed. Also that the air vent to the
outside is not obstructed.

Sometimes a screen spark guard on the top of a chimney will clog. It may
look fine from below, but get up on roof and you will see that it is
clogged so little or no smoke can get out the chimney. I removed my spark
guard because it was always clogging.


Just be aware that this can be an insurance or safety concern. I expect
your insurance company would be looking closely at your chimney if you
claimed damage from a roof fire or similar accident. Best to remove the
screen and clean it, or replace it.

In our dry, remote area, one spark out the chimney could burn hundreds of
acres of pine forest, including homes downwind of us . Fortunately, summers
are hot enough that fires are not required until cool rainy weather hits in
Autumn.


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Improving a lawn dean Home Repair 8 April 13th 07 11:11 PM
draft under gas fireplace [email protected] Home Repair 2 February 8th 07 07:18 PM
Gas fireplace draft +blocking vent? [email protected] Home Repair 0 January 8th 06 03:09 PM
Improving AC in one room Tony Home Ownership 2 June 16th 05 07:46 PM
improving WWVB reception Chris Campbell Electronics Repair 7 August 7th 03 04:17 PM


All times are GMT +1. The time now is 09:17 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"