I have to cut off a section of cast iron waste pipe in my attic to tie
in a vent .My concern is when I cut off the section of pipe, the weight of the upper part of pipe would cause it to possible come loose from the roof flashing and sink, thus causing a roof leak. The last thing I want to do is open up a can of worms by doing this job. I was wondering if I should be concerned or if anyone else has done a job like this, what advice to offer. Thanks |
Cutting cast iron pipe w/o causing roof leak
Mikepier wrote:
I have to cut off a section of cast iron waste pipe in my attic to tie in a vent .My concern is when I cut off the section of pipe, the weight of the upper part of pipe would cause it to possible come loose from the roof flashing and sink, thus causing a roof leak. The last thing I want to do is open up a can of worms by doing this job. I was wondering if I should be concerned or if anyone else has done a job like this, what advice to offer. Thanks I would fabricate a permanent support for the upper section. Heavy steel strap clamp around it tied up to rafters. If you put turnbuckles in the tie section you can preload it before cutting. If you can get on the roof to work, much better to simply replace the section with PVC and a new rubber flashing boot. Jim |
Cutting cast iron pipe w/o causing roof leak
"Mikepier" wrote in message
ups.com... I have to cut off a section of cast iron waste pipe in my attic to tie in a vent .My concern is when I cut off the section of pipe, the weight of the upper part of pipe would cause it to possible come loose from the roof flashing and sink, thus causing a roof leak. The last thing I want to do is open up a can of worms by doing this job. I was wondering if I should be concerned or if anyone else has done a job like this, what advice to offer. Thanks I like Jim's idea, but I also think that even the slightest movement of the pipe could affect the integrity of the seal around the flashing. You'd still want to get up there with the appropriate caulk when the job's done. |
Cutting cast iron pipe w/o causing roof leak
On Thu, 20 Sep 2007 08:34:26 -0700, Mikepier wrote:
I have to cut off a section of cast iron waste pipe in my attic to tie in a vent .My concern is when I cut off the section of pipe, the weight of the upper part of pipe would cause it to possible come loose from the roof flashing and sink, thus causing a roof leak. The last thing I want to do is open up a can of worms by doing this job. I was wondering if I should be concerned or if anyone else has done a job like this, what advice to offer. Thanks You didn't state exactly where you are working on the vent pipe. Chances are you will see very little, if any, movement if you work below existing vents tied into the main pipe. It would still be a wise choice to secure the uppermost part of the pipe with strap supports designed to hold pipes securely. A reciprocating saw would seem to move the pipe less than doing so with a handsaw. I did exactly what you are doing several years back. That vent was cast iron. I had to cut the pipe in the basement to reroute tub and stool. There were enough pipes above me to support the vent without moving. Reflashing or caulking the existing flash when done makes sense. |
Cutting cast iron pipe w/o causing roof leak
On Thu, 20 Sep 2007 16:02:54 GMT, franz frippl
wrote: On Thu, 20 Sep 2007 08:34:26 -0700, Mikepier wrote: I have to cut off a section of cast iron waste pipe in my attic to tie in a vent .My concern is when I cut off the section of pipe, the weight of the upper part of pipe would cause it to possible come loose from the roof flashing and sink, thus causing a roof leak. The last thing I want to do is open up a can of worms by doing this job. I was wondering if I should be concerned or if anyone else has done a job like this, what advice to offer. Thanks You didn't state exactly where you are working on the vent pipe. Chances are you will see very little, if any, movement if you work below existing vents tied into the main pipe. It would still be a wise choice to secure the uppermost part of the pipe with strap supports designed to hold pipes securely. A reciprocating saw would seem to move the pipe less than doing so with a handsaw. I did exactly what you are doing several years back. That vent was cast iron. I had to cut the pipe in the basement to reroute tub and stool. There were enough pipes above me to support the vent without moving. Reflashing or caulking the existing flash when done makes sense. If all you are doing is adding a vent, you can buy strap around devices. Then cut a square hole in the cast pipe with an angle grinder and attach the "strap on". You dont need to cut the whole pipe. After all, it's only a vent. |
Cutting cast iron pipe w/o causing roof leak
On Sep 20, 2:44 pm, wrote:
On Thu, 20 Sep 2007 16:02:54 GMT, franz frippl wrote: On Thu, 20 Sep 2007 08:34:26 -0700, Mikepier wrote: I have to cut off a section of cast iron waste pipe in my attic to tie in a vent .My concern is when I cut off the section of pipe, the weight of the upper part of pipe would cause it to possible come loose from the roof flashing and sink, thus causing a roof leak. The last thing I want to do is open up a can of worms by doing this job. I was wondering if I should be concerned or if anyone else has done a job like this, what advice to offer. Thanks You didn't state exactly where you are working on the vent pipe. Chances are you will see very little, if any, movement if you work below existing vents tied into the main pipe. It would still be a wise choice to secure the uppermost part of the pipe with strap supports designed to hold pipes securely. A reciprocating saw would seem to move the pipe less than doing so with a handsaw. I did exactly what you are doing several years back. That vent was cast iron. I had to cut the pipe in the basement to reroute tub and stool. There were enough pipes above me to support the vent without moving. Reflashing or caulking the existing flash when done makes sense. If all you are doing is adding a vent, you can buy strap around devices. Then cut a square hole in the cast pipe with an angle grinder and attach the "strap on". You dont need to cut the whole pipe. After all, it's only a vent.- Hide quoted text - - Show quoted text - Is there a place online I can find out more about this? |
Cutting cast iron pipe w/o causing roof leak
"Mikepier" wrote in message
ps.com... On Sep 20, 2:44 pm, wrote: On Thu, 20 Sep 2007 16:02:54 GMT, franz frippl wrote: On Thu, 20 Sep 2007 08:34:26 -0700, Mikepier wrote: I have to cut off a section of cast iron waste pipe in my attic to tie in a vent .My concern is when I cut off the section of pipe, the weight of the upper part of pipe would cause it to possible come loose from the roof flashing and sink, thus causing a roof leak. The last thing I want to do is open up a can of worms by doing this job. I was wondering if I should be concerned or if anyone else has done a job like this, what advice to offer. Thanks You didn't state exactly where you are working on the vent pipe. Chances are you will see very little, if any, movement if you work below existing vents tied into the main pipe. It would still be a wise choice to secure the uppermost part of the pipe with strap supports designed to hold pipes securely. A reciprocating saw would seem to move the pipe less than doing so with a handsaw. I did exactly what you are doing several years back. That vent was cast iron. I had to cut the pipe in the basement to reroute tub and stool. There were enough pipes above me to support the vent without moving. Reflashing or caulking the existing flash when done makes sense. If all you are doing is adding a vent, you can buy strap around devices. Then cut a square hole in the cast pipe with an angle grinder and attach the "strap on". You dont need to cut the whole pipe. After all, it's only a vent.- Hide quoted text - - Show quoted text - Is there a place online I can find out more about this? Open your yellow pages phone book and find a plumbing supply store. Go there and ask. |
Cutting cast iron pipe w/o causing roof leak
"JoeSpareBedroom" wrote in message Open your yellow pages phone book and find a plumbing supply store. Go there and ask. Oh man, that requires interacting with real people. |
Cutting cast iron pipe w/o causing roof leak
"Edwin Pawlowski" wrote in message
news:oKAIi.3456$yO2.2867@trndny01... "JoeSpareBedroom" wrote in message Open your yellow pages phone book and find a plumbing supply store. Go there and ask. Oh man, that requires interacting with real people. I'm gettin' a headache just thinking about it. |
Cutting cast iron pipe w/o causing roof leak
On 2007-09-20, Speedy Jim wrote:
If you can get on the roof to work, much better to simply replace the section with PVC and a new rubber flashing boot. DWV PVC as roof vent requires painting, as the material is not made with UV inhibitors? Cheers, Wayne |
Cutting cast iron pipe w/o causing roof leak
On Thu, 20 Sep 2007 12:01:11 -0700, Mikepier
wrote: On Sep 20, 2:44 pm, wrote: On Thu, 20 Sep 2007 16:02:54 GMT, franz frippl wrote: On Thu, 20 Sep 2007 08:34:26 -0700, Mikepier wrote: I have to cut off a section of cast iron waste pipe in my attic to tie in a vent .My concern is when I cut off the section of pipe, the weight of the upper part of pipe would cause it to possible come loose from the roof flashing and sink, thus causing a roof leak. The last thing I want to do is open up a can of worms by doing this job. I was wondering if I should be concerned or if anyone else has done a job like this, what advice to offer. Thanks You didn't state exactly where you are working on the vent pipe. Chances are you will see very little, if any, movement if you work below existing vents tied into the main pipe. It would still be a wise choice to secure the uppermost part of the pipe with strap supports designed to hold pipes securely. A reciprocating saw would seem to move the pipe less than doing so with a handsaw. I did exactly what you are doing several years back. That vent was cast iron. I had to cut the pipe in the basement to reroute tub and stool. There were enough pipes above me to support the vent without moving. Reflashing or caulking the existing flash when done makes sense. If all you are doing is adding a vent, you can buy strap around devices. Then cut a square hole in the cast pipe with an angle grinder and attach the "strap on". You dont need to cut the whole pipe. After all, it's only a vent.- Hide quoted text - - Show quoted text - Is there a place online I can find out more about this? Possibly..... There are some plumbing supply stores online. However, I'd check your local plumbing supply places. These things are commonly used. I dont know the exact name for them, but I have seen them. It's basically just a device that fits around the cast iron pipe. It fits around about half the pipe, has a rubber gasket, and uses large hose clamps to attach it. There will be a 1.5 or 2 inch threaded hole in the side to attach your pipe. They also make similar devices for water pipes, so it's easier to attach a water source to an ice maker. Those are called "saddle valves", but they have an actual valve built in. Knowing that, these drain pipe devices could be called "saddle" (something). Just a guess. |
Cutting cast iron pipe w/o causing roof leak
on 9/20/2007 4:29 PM Edwin Pawlowski said the following:
"JoeSpareBedroom" wrote in message Open your yellow pages phone book and find a plumbing supply store. Go there and ask. Oh man, that requires interacting with real people. I hate real people.Cyber people are better. -- Bill In Hamptonburgh, NY To email, remove the double zeroes after @ |
All times are GMT +1. The time now is 03:20 AM. |
Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004 - 2014 DIYbanter