[email protected] July 29th 07 12:10 PM

Lost oil from central a/c unit
 
Hi ,Not sure what I did wrong but I added freon for a frozen Rheem 3
ton central a/c unit, After the ice melted in the aie handler the
pressure on the low side shot up to 100 from 40. I decided to remove
some freon from the unit. I used the low pressure side to remove the
freon . After a while I noticed that I lost about 6 0z. of oil. So I
decided to remove freon using the high pressure side. That worked
alot better with very little oil loss. Finally I got the low pressure
side to about 65 and the unit is working well. I have 2 questions
now., How do I replace the oil back the the central a/c unit? And Why
did the pressure rise after the ice melted in the air handler. Any
advice would help. Ray


Moe Jones July 29th 07 03:29 PM

Lost oil from central a/c unit
 
wrote:
Hi ,Not sure what I did wrong but I added freon for a frozen Rheem 3
ton central a/c unit, After the ice melted in the aie handler the
pressure on the low side shot up to 100 from 40. I decided to remove
some freon from the unit. I used the low pressure side to remove the
freon . After a while I noticed that I lost about 6 0z. of oil. So I
decided to remove freon using the high pressure side. That worked
alot better with very little oil loss. Finally I got the low pressure
side to about 65 and the unit is working well. I have 2 questions
now., How do I replace the oil back the the central a/c unit? And Why
did the pressure rise after the ice melted in the air handler. Any
advice would help. Ray


Becareful when you are charging your unit. If you do not properly hook up
your gages to your system you can easly inject air into the system and then
you will be having some major repairs needed.

I first would ask myself why the system needed a top off and do you see any
signs of a leal?

To add oil to your system you need a injector.

--
Moe Jones
HVAC Service Technician
Energy Equalizers Inc.
Houston, Texas
www.EnergyEqualizers.com



No Name July 29th 07 05:24 PM

Lost oil from central a/c unit
 

wrote in message
oups.com...
Hi ,Not sure what I did wrong but I added freon for a frozen Rheem 3
ton central a/c unit, After the ice melted in the aie handler the
pressure on the low side shot up to 100 from 40. I decided to remove
some freon from the unit. I used the low pressure side to remove the
freon . After a while I noticed that I lost about 6 0z. of oil. So I
decided to remove freon using the high pressure side. That worked
alot better with very little oil loss. Finally I got the low pressure
side to about 65 and the unit is working well. I have 2 questions
now., How do I replace the oil back the the central a/c unit? And Why
did the pressure rise after the ice melted in the air handler. Any
advice would help. Ray



The first thing you did wrong was mess with something you shouldn't have.

The second thing makes me think you should call the EPA and tell them what
you've just done.

Ever heard of the "Montreal Protocol"?



Moe Jones July 29th 07 05:42 PM

Lost oil from central a/c unit
 
kjpro @ usenet.com wrote:
..

The second thing makes me think you should call the EPA and tell them
what you've just done.

Ever heard of the "Montreal Protocol"?


Tell me if I am right, if he's neighbor had filmed him with a camera and
turned him in to EPA, that neighbor could have gotten a reward of $10,000 or
is the $10,000 is the fine that EPA would have fined him?

--
Moe Jones
HVAC Service Technician
Energy Equalizers Inc.
Houston, Texas
www.EnergyEqualizers.com



edbedb July 29th 07 06:36 PM

Lost oil from central a/c unit
 
kjpro @ usenet.com wrote:


The first thing you did wrong was mess with something you shouldn't have.

The second thing makes me think you should call the EPA and tell them what
you've just done.

Ever heard of the "Montreal Protocol"?


Little wanna' be Stalinist 'narcing out his neighbors. Worthless piece
of **** as a
human being.




No Name July 29th 07 07:03 PM

Lost oil from central a/c unit
 

"edbedb" wrote in message
. ..
kjpro @ usenet.com wrote:


The first thing you did wrong was mess with something you shouldn't

have.

The second thing makes me think you should call the EPA and tell them

what
you've just done.

Ever heard of the "Montreal Protocol"?


Little wanna' be Stalinist 'narcing out his neighbors. Worthless piece
of **** as a
human being.



What's your problem, ****face?



jJim McLaughlin July 29th 07 08:05 PM

Lost oil from central a/c unit
 
ROTFL.

You have no ability to control your emotion and rage.

Almost every touch to your keyboard
involves you calling someone who dis agrrees
with you an asshole or ****face.

You are one sick puppy.


kjpro @ usenet.com wrote:

"edbedb" wrote in message
. ..

kjpro @ usenet.com wrote:


The first thing you did wrong was mess with something you shouldn't


have.

The second thing makes me think you should call the EPA and tell them


what

you've just done.

Ever heard of the "Montreal Protocol"?


Little wanna' be Stalinist 'narcing out his neighbors. Worthless piece
of **** as a
human being.




What's your problem, ****face?



[email protected] July 30th 07 03:34 AM

Lost oil from central a/c unit
 
On Jul 29, 11:42 am, "Moe Jones" wrote:
kjpro @ usenet.com wrote:

.



The second thing makes me think you should call the EPA and tell them
what you've just done.


Ever heard of the "Montreal Protocol"?


Tell me if I am right, if he's neighbor had filmed him with a camera and
turned him in to EPA, that neighbor could have gotten a reward of $10,000 or
is the $10,000 is the fine that EPA would have fined him?

--


So let me get this straight, The Federal Government won't
do anything about people entering this country illegally but
they're going to go after a citizen who leaked a little R-22 ?
That sounds about right. Better yet, he should be caught
with naked pictures of his small children in the bathtub.
It would make the national headlines. "Child Porn Pervert
Caught Murdering Poor Little Ozones". The only actions
taken by the EPA that I've read about lately in the HVAC
news publications have been against large outfits who
make mistakes in their paperwork. It wouldn't surprise me
at all if some EPA bureaucrat, looking to boost his career,
went after some little guy for the publicity. Anyway, that's
government for you.

[8~{} Uncle Monster





No Name July 30th 07 08:48 AM

Lost oil from central a/c unit
 

"jJim McLaughlin" wrote in message
. ..
ROTFL.

You have no ability to control your emotion and rage.

Almost every touch to your keyboard
involves you calling someone who dis agrrees
with you an asshole or ****face.

You are one sick puppy.



Control emotion and rage.

I'm posting a freaking message, who says I'm upset? LOL




All times are GMT +1. The time now is 01:04 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.