Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6
Default advice on replacement a/c and copper line to outside

We are replacing our 15 yr old 3 ton Trane 10 seer (still works but
not efficient and underpowered) with an American Std 3 1/2 ton heat
pump with variable speed air handler 14 seer. Air handler in the
garage, compressor outside in backyard about a 16 ft. straight line.
The copper used to run underground (straight line); a few years ago we
had a leak and before I had a chance to talk with the repair guys they
ran a 50 ft length around the garage, through the utility room then
out to the back. This has worked but I have always wondered about the
efficiency. Since we are going to the expense of repl the old unit I
am wondering if it would be worth it (does it even matter?) to run a
new line of a much shorter distance 18 - 25 ft depending if we go
underground or above. Does this create a higher load? Thanks - Bill

  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 5
Default advice on replacement a/c and copper line to outside

On Jun 14, 6:15 pm, Bill wrote:
We are replacing our 15 yr old 3 ton Trane 10 seer (still works but
not efficient and underpowered) with an American Std 3 1/2 ton heat
pump with variable speed air handler 14 seer. Air handler in the
garage, compressor outside in backyard about a 16 ft. straight line.
The copper used to run underground (straight line); a few years ago we
had a leak and before I had a chance to talk with the repair guys they
ran a 50 ft length around the garage, through the utility room then
out to the back. This has worked but I have always wondered about the
efficiency. Since we are going to the expense of repl the old unit I
am wondering if it would be worth it (does it even matter?) to run a
new line of a much shorter distance 18 - 25 ft depending if we go
underground or above. Does this create a higher load? Thanks - Bill


I think when you increase from 3 to 3.5 ton they will probably want to
replace the lineset. I think the 3.5 ton will require a 1 and 1/8th
inch suction line. And yes I would want a shorter more direct run....I
dont know if you would notice much in an efficiency increase but a
shorter more direct route leaves less joints in the
tubing...hopefully....

Also...a new lineset will leave less chance of leaving behind any
contamination from the old system if it wasnt as clean as dry as it
should be.

  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 10,530
Default advice on replacement a/c and copper line to outside

I hesitate to post with someone named "corny the clown" on a
matter of technical advice. However, I do also suggest the new
line set.

Oh, if your kid's got a hot appendix, please don't save money by
having Corny The Clown take it out.

--

Christopher A. Young
You can't shout down a troll.
You have to starve them.
..

wrote in message
ups.com...
:
: I think when you increase from 3 to 3.5 ton they will probably
want to
: replace the lineset. I think the 3.5 ton will require a 1 and
1/8th
: inch suction line. And yes I would want a shorter more direct
run....I
: dont know if you would notice much in an efficiency increase
but a
: shorter more direct route leaves less joints in the
: tubing...hopefully....
:
: Also...a new lineset will leave less chance of leaving behind
any
: contamination from the old system if it wasnt as clean as dry
as it
: should be.
:


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Re-line a copper kettle? [email protected] Metalworking 2 May 28th 06 07:44 PM
Brief bad smell from new copper water line Wayne Whitney Home Repair 3 March 12th 06 12:20 AM
how to test gas copper line for leaks renux Home Repair 20 January 26th 06 10:23 PM
Pex service line to soft copper Art M Home Repair 3 September 29th 05 10:56 PM