Greg Oliva April 4th 07 05:25 AM

Rattling water pipe inside wall
 
I had a bathroom added to my house as part of an addition last summer.
The copper hot water pipe rattles inside the wall; at least it does when the
valve under the sink is not fully open. My wife likes to turn it down
halfway or so. When the valve is half closed, running the hot water in the
sink cause the pipe to emit a loud "chatter" in the wall. The contractor
who did the job, and his plumbing subcontractor, have apparently told my
wife that the valve should be open all the way for normal operation. They
say of course the pipe will rattle when the hot water valve is turned down.
I suspect the pipe somewhere inside the wall was not properly secured. What
is the real story here?



buffalobill April 4th 07 09:04 AM

Rattling water pipe inside wall
 
On Apr 4, 12:25 am, "Greg Oliva" wrote:
I had a bathroom added to my house as part of an addition last summer.
The copper hot water pipe rattles inside the wall; at least it does when the
valve under the sink is not fully open. My wife likes to turn it down
halfway or so. When the valve is half closed, running the hot water in the
sink cause the pipe to emit a loud "chatter" in the wall. The contractor
who did the job, and his plumbing subcontractor, have apparently told my
wife that the valve should be open all the way for normal operation. They
say of course the pipe will rattle when the hot water valve is turned down.
I suspect the pipe somewhere inside the wall was not properly secured. What
is the real story here?


if she likes to turn it down, let's guess:
she may be trying to balance the hot and cold to match her preferred
lever handle settings or not get splashed. what is her problem
exactly, and then what is her reasoning? can it be accomplished by a
different sink fixture with a single handle? can it be accomplished
quietly instead by adjusting the basement hot riser stop?
sometimes the rate of water flow past a loose washer on a stop under
the sink might cause this.
sometimes "water hammer" solutions are what you seek, in which the
supply pipes continue above the sink into a small dead end of air in
the water pipe stub which operates as a shock absorber. there are add-
on devices for this water hammer problem. sometimes if you are lucky
enough to have plenty of water pressure to hose the driveway full
blast [or water the entire 80-foot yard from the porch], the high
pressure within the indoor fixtures requires some pressure reduction.
but first, i would listen carefully to determine where the chatter
starts. i would try removing the rubber washer from the under-sink
stop. try removing the stop washer from the hot water riser to the
noisy fixture at the basement. try removing the aerator at the fixture
to change the water flow rate.
for fun, i would buy an inexpensive water pressure meter you can screw
onto the garden hose sillcock to see what the PSI pounds per square
inch pressure is. gallons per minute GPM is the flow rate.
new shutoffs may not have rubber washers within. full-flow ball type
water valves with lever handles can provide better flow than straight
stops.





Joseph Meehan April 4th 07 01:07 PM

Rattling water pipe inside wall
 
Greg Oliva wrote:
I had a bathroom added to my house as part of an addition last
summer. The copper hot water pipe rattles inside the wall; at least it
does
when the valve under the sink is not fully open. My wife likes to
turn it down halfway or so. When the valve is half closed, running
the hot water in the sink cause the pipe to emit a loud "chatter" in
the wall. The contractor who did the job, and his plumbing
subcontractor, have apparently told my wife that the valve should be
open all the way for normal operation. They say of course the pipe
will rattle when the hot water valve is turned down. I suspect the
pipe somewhere inside the wall was not properly secured. What is the
real story here?


There are a lot of possibilities about what is the problem with the
plumbing. Buffalo did a good job on those. However I think it is clear
that from your description there is a real problem with the contractor and
his plumber. There is a problem and it is not your wife.

--
Joseph Meehan

Dia 's Muire duit




Speedy Jim April 4th 07 03:34 PM

Rattling water pipe inside wall
 
Greg Oliva wrote:
I had a bathroom added to my house as part of an addition last summer.
The copper hot water pipe rattles inside the wall; at least it does when the
valve under the sink is not fully open. My wife likes to turn it down
halfway or so. When the valve is half closed, running the hot water in the
sink cause the pipe to emit a loud "chatter" in the wall. The contractor
who did the job, and his plumbing subcontractor, have apparently told my
wife that the valve should be open all the way for normal operation. They
say of course the pipe will rattle when the hot water valve is turned down.
I suspect the pipe somewhere inside the wall was not properly secured. What
is the real story here?



The contractor is 100% correct.

Stop valves are intended for "stopping", not modulating.
Typically, the washer in them is only loosely attached to
the stem. Partly closed, the washer can "flap in the breeze"
creating the chatter you have.

If there is some other condition (water pressure, temp)
requiring modulation, fix that problem.

Or....install a nice ball valve shut off under the sink
for the wife. But don't expect the contractor to pay for it.

Jim

Joseph Meehan April 4th 07 07:27 PM

Rattling water pipe inside wall
 
Speedy Jim wrote:
Greg Oliva wrote:
I had a bathroom added to my house as part of an addition last
summer. The copper hot water pipe rattles inside the wall; at least
it does when the valve under the sink is not fully open. My wife
likes to turn it down halfway or so. When the valve is half closed,
running the hot water in the sink cause the pipe to emit a loud
"chatter" in the wall. The contractor who did the job, and his
plumbing subcontractor, have apparently told my wife that the valve
should be open all the way for normal operation. They say of course
the pipe will rattle when the hot water valve is turned down. I
suspect the pipe somewhere inside the wall was not properly secured.
What is the real story here?


The contractor is 100% correct.

Stop valves are intended for "stopping", not modulating.


Opps, I missed that "valve under the sink" part. Please consider my
observations in my prior message suspect.


Typically, the washer in them is only loosely attached to
the stem. Partly closed, the washer can "flap in the breeze"
creating the chatter you have.

If there is some other condition (water pressure, temp)
requiring modulation, fix that problem.

Or....install a nice ball valve shut off under the sink
for the wife. But don't expect the contractor to pay for it.

Jim


--
Joseph Meehan

Dia 's Muire duit