Default Heat duct using only silver tape no screws, and oven hood vent question.

Hi, I don't know that much about home repair in general. I am having
some work done, and I want to know if it is done correctly or not.

I am having a heating vent installed in a new finished office. He is
using metal duct, but he is only taping it closed and together. It is
heat tape with red print on it but he is not using any screws. I
question him about this because all of my other duct work uses screws,
but he tells me that using tape is better better because it prevents
all leaks? My question is, if this is really the right way to do it?

And my oven hood vent, we originally agreed to create a new vent for
it through my vaulted ceiling, then he said we could go through the
wall, and then through my unheated attic. I was fine with that, but
upon further investigation, I found out he connected it to my bathroom
4" bathroom duct. I talked to him, and he will change it to have
it's own duct. He also used an insulated flexible duct, when I did
research, I found it stated that you should use hard metal duct. He
said it was better to use flexible insulated duct so you don't get
return cold air? Is this right, or should I ask for rigid metal
duct?

Can you just glue and screw plywood to a cement basement or do you
need a moisure barrier between the plywood and cement? He is doing
this to raise the level of my office to the same level as the tile in
my hallway so I can float engineer hardwood on it.

Just want to make sure I am getting my home improvement done
correctly. Thanks,

Lulu

  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 766
Default Heat duct using only silver tape no screws, and oven hood vent question.

wrote:
Hi, I don't know that much about home repair in general. I am having
some work done, and I want to know if it is done correctly or not.

I am having a heating vent installed in a new finished office. He is
using metal duct, but he is only taping it closed and together. It is
heat tape with red print on it but he is not using any screws. I
question him about this because all of my other duct work uses screws,
but he tells me that using tape is better better because it prevents
all leaks? My question is, if this is really the right way to do it?


Normally for air ducts I use both. I would guess, that if the ducts
were otherwise secure without the tape, that should be enough. If not, I
would want both.


And my oven hood vent, we originally agreed to create a new vent for
it through my vaulted ceiling, then he said we could go through the
wall, and then through my unheated attic. I was fine with that, but
upon further investigation, I found out he connected it to my bathroom
4" bathroom duct. I talked to him, and he will change it to have
it's own duct. He also used an insulated flexible duct, when I did
research, I found it stated that you should use hard metal duct. He
said it was better to use flexible insulated duct so you don't get
return cold air? Is this right, or should I ask for rigid metal
duct?


You got a real winner there. Rigid only!



Can you just glue and screw plywood to a cement basement or do you
need a moisure barrier between the plywood and cement? He is doing
this to raise the level of my office to the same level as the tile in
my hallway so I can float engineer hardwood on it.


Ill bet the flooring company will specify a vapor barrier. I would
demand one.


Just want to make sure I am getting my home improvement done
correctly. Thanks,

Lulu


--
Joseph Meehan

Dia 's Muire duit



  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 24
Default Heat duct using only silver tape no screws, and oven hood vent question.


wrote in message
oups.com...
| Hi, I don't know that much about home repair in general. I am having
| some work done, and I want to know if it is done correctly or not.
|
| I am having a heating vent installed in a new finished office. He is
| using metal duct, but he is only taping it closed and together. It is
| heat tape with red print on it but he is not using any screws. I
| question him about this because all of my other duct work uses screws,
| but he tells me that using tape is better better because it prevents
| all leaks? My question is, if this is really the right way to do it?


no it is not the correct way
the round ducts should have 3 screws in them.
rectangular ducts should have 4 screws.
then sealed with duct seal NOT heat tape.
heat tape is for the insulation that goes over the ducting.





|
| And my oven hood vent, we originally agreed to create a new vent for
| it through my vaulted ceiling, then he said we could go through the
| wall, and then through my unheated attic. I was fine with that, but
| upon further investigation, I found out he connected it to my bathroom
| 4" bathroom duct. I talked to him, and he will change it to have
| it's own duct. He also used an insulated flexible duct, when I did
| research, I found it stated that you should use hard metal duct.



stainless steel ducting is best for grease from a hood.
never use plastic or vinyl ducting for a hood.
the shorter the distance of the ducting, the more efficient it will be.





He
| said it was better to use flexible insulated duct so you don't get
| return cold air?

He is an ass
or you are a troll
which is it?
an in-line damper is installed for back drafts





Is this right, or should I ask for rigid metal
| duct?

stainless steel ducting is best for grease from a hood.
never use plastic or vinyl ducting for a hood.
insist on metal.




|
| Can you just glue and screw plywood to a cement basement or do you
| need a moisure barrier between the plywood and cement?

plywood on a cement floor?
why bother?
install the new floor directly over the concrete with thicker padding
for comfort..
vapor barrier over concrete - absolutely not





He is doing
| this to raise the level of my office to the same level as the tile in
| my hallway so I can float engineer hardwood on it.
|
| Just want to make sure I am getting my home improvement done
| correctly. Thanks,

sounds like you really picked a winner to do the work for you.
good luck with this project
(I mean, your contractor sounds like a science project)


|
| Lulu
|


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
New HVAC question - duct heat/colling loss in attic MC Home Repair 10 May 5th 05 04:53 AM
Sealing Round Metal Duct Joints On Forced Hot Air Furnace (other than duct tape)? Robert11 Home Repair 7 April 21st 05 11:24 PM
Vent Hood for 4&1/4 inch duct? willshak Home Repair 0 October 3rd 04 10:43 PM
Strange particles from air vent and return air duct sealant question Jack Home Repair 5 December 3rd 03 01:26 AM
Strange particles from air vent and return air duct sealant question Jack Home Ownership 1 December 2nd 03 06:11 PM


All times are GMT +1. The time now is 03:05 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"