hoops October 20th 06 06:58 PM

hot water heater blow off valve
 
i have a new tank and would like to run any eventual output from the valve
into my sump pump (about a 7' run).

the valve's got a 3/4 female end. i'd like to use pex, but i don't have a
tool, nor the fittings.

i have a suitable piece of 1/2" pex. i know the pex should go around a
connector and would be help in place with a ring that is pushed into place.


can i get away with stepping down the 3/4 to a 3/8" barrel which i'd insert
into the 1/2 pex and hold in place with a hose connector? i don't think the
output will be under severe pressure, and this is a simple solution.

thots? thanks



Edwin Pawlowski October 20th 06 07:06 PM

hot water heater blow off valve
 

"hoops" wrote in message
...
i have a new tank and would like to run any eventual output from the valve
into my sump pump (about a 7' run).

the valve's got a 3/4 female end. i'd like to use pex, but i don't have a
tool, nor the fittings.

i have a suitable piece of 1/2" pex. i know the pex should go around a
connector and would be help in place with a ring that is pushed into
place.


can i get away with stepping down the 3/4 to a 3/8" barrel which i'd
insert into the 1/2 pex and hold in place with a hose connector? i don't
think the output will be under severe pressure, and this is a simple
solution.

thots? thanks


You do not want to restrict the outlet. Safety devices are sized the way
they are for a reason; to take away the overload with no restrictions.

Since this is a blow-off, not a continuous use line, PVC would work as well.
Hell, I'd probably just run a garden hose for what you are doing.



hoops October 20th 06 07:36 PM

hot water heater blow off valve
 
i think the water's too hot for a garden hose. are their fitting for
threaded pipe to pvc?

"Edwin Pawlowski" wrote in message
news:se8_g.17$bb.16@trnddc03...

"hoops" wrote in message
...
i have a new tank and would like to run any eventual output from the valve
into my sump pump (about a 7' run).

the valve's got a 3/4 female end. i'd like to use pex, but i don't have
a tool, nor the fittings.

i have a suitable piece of 1/2" pex. i know the pex should go around a
connector and would be help in place with a ring that is pushed into
place.


can i get away with stepping down the 3/4 to a 3/8" barrel which i'd
insert into the 1/2 pex and hold in place with a hose connector? i don't
think the output will be under severe pressure, and this is a simple
solution.

thots? thanks


You do not want to restrict the outlet. Safety devices are sized the way
they are for a reason; to take away the overload with no restrictions.

Since this is a blow-off, not a continuous use line, PVC would work as
well. Hell, I'd probably just run a garden hose for what you are doing.




Craven Morehead October 20th 06 07:43 PM

hot water heater blow off valve
 
The code here (which I believe is typical in U.S.) is the T&P pipe must be
the same size & material as the supply line, FWIW.

"hoops" wrote in message
...
i have a new tank and would like to run any eventual output from the valve
into my sump pump (about a 7' run).

the valve's got a 3/4 female end. i'd like to use pex, but i don't have a
tool, nor the fittings.

i have a suitable piece of 1/2" pex. i know the pex should go around a
connector and would be help in place with a ring that is pushed into
place.


can i get away with stepping down the 3/4 to a 3/8" barrel which i'd
insert into the 1/2 pex and hold in place with a hose connector? i don't
think the output will be under severe pressure, and this is a simple
solution.

thots? thanks




Edwin Pawlowski October 20th 06 08:06 PM

hot water heater blow off valve
 

"hoops" wrote in message
...
i think the water's too hot for a garden hose. are their fitting for
threaded pipe to pvc?


Technically, you are correct. But in reality, it takes but a few seconds
for a blow off. It is not a supply line, there is no pressure buildup, and
the hose is not going to melt in 30 seconds. It is merely a diversion rather
than have the water hit the floor as would happen in hundreds of thousands
of households.

Yes, there are the PVC adapters.



Mark October 20th 06 10:01 PM

hot water heater blow off valve
 

Craven Morehead wrote:
The code here (which I believe is typical in U.S.) is the T&P pipe must be
the same size & material as the supply line, FWIW.

"hoops" wrote in message
...
i have a new tank and would like to run any eventual output from the valve
into my sump pump (about a 7' run).

the valve's got a 3/4 female end. i'd like to use pex, but i don't have a
tool, nor the fittings.

i have a suitable piece of 1/2" pex. i know the pex should go around a
connector and would be help in place with a ring that is pushed into
place.


can i get away with stepping down the 3/4 to a 3/8" barrel which i'd
insert into the 1/2 pex and hold in place with a hose connector? i don't
think the output will be under severe pressure, and this is a simple
solution.

thots? thanks


you can just put a larger pipe under it with an air gap in a funnel
like fashion to catch the water from the blow off valve ....this
eliminates any chance of a restriction blocking the saftey blow off...

Mark


HeyBub October 20th 06 10:32 PM

hot water heater blow off valve
 
hoops wrote:
i think the water's too hot for a garden hose. are their fitting for
threaded pipe to pvc?


Don't you use a garden hose to DRAIN the water heater? Have I been abusing
my hose all these years? What will the cops do if they find out?



Lawrence October 20th 06 10:44 PM

hot water heater blow off valve
 

hoops wrote:
i have a new tank and would like to run any eventual output from the valve
into my sump pump (about a 7' run).

the valve's got a 3/4 female end. i'd like to use pex, but i don't have a
tool, nor the fittings.

i have a suitable piece of 1/2" pex. i know the pex should go around a
connector and would be help in place with a ring that is pushed into place.


Just use pvc and glue it together. cheap and easy.


Harry K October 21st 06 03:19 AM

hot water heater blow off valve
 

Lawrence wrote:
hoops wrote:
i have a new tank and would like to run any eventual output from the valve
into my sump pump (about a 7' run).

the valve's got a 3/4 female end. i'd like to use pex, but i don't have a
tool, nor the fittings.

i have a suitable piece of 1/2" pex. i know the pex should go around a
connector and would be help in place with a ring that is pushed into place.


Just use pvc and glue it together. cheap and easy.


Yep, that is what I did. Makes a very neat installation. I did use
CPVC though but that is overkill unless an inspector gets his panties
in a wad seeing PVC on hot water lines.

Harry K


Don Young October 21st 06 04:09 AM

hot water heater blow off valve
 

"hoops" wrote in message
...
i have a new tank and would like to run any eventual output from the valve
into my sump pump (about a 7' run).

the valve's got a 3/4 female end. i'd like to use pex, but i don't have a
tool, nor the fittings.

i have a suitable piece of 1/2" pex. i know the pex should go around a
connector and would be help in place with a ring that is pushed into
place.


can i get away with stepping down the 3/4 to a 3/8" barrel which i'd
insert into the 1/2 pex and hold in place with a hose connector? i don't
think the output will be under severe pressure, and this is a simple
solution.

thots? thanks

Keep in mind that if the valve performs its intended safety function, to
prevent rupture of the tank when the heating system fails to turn off,
there could be a lot of very hot water and steam blowing out of it at pretty
high pressure. A large, rigid, well secured line is kinda nice to have and
is required by some codes.

Don Young

Don Young