Martin January 4th 06 05:33 AM

Kitchen faucet losing pressure
 
We have kitchen faucet that is the farthest one from the water entry point
in the house. It always has seemed to have a little lower pressure than
several others we have in the house, but recently the flow in this one has
dropped drastically. I was wondering if this might be due to something
wrong with mixing device in the faucet and whether it needs to be replaced.

The faucet is a Kohler single hole mounting, single lever type with a pull
out spray head. The mixing cartridge is a plastic assembly with 2 O-rings
on the bottom. I can see 2 little springs inside, but the assembly doesn't
look like it was meant to be taken apart so I couldn't check for
obstructions inside.

Is it likely that just replacing the cartridge will fix it? I've seen them
at Home Depot and Lowes. Or should I be looking somewhere else for the
cause.

Suggestions would be appreciated.







gib January 4th 06 05:39 AM

Kitchen faucet losing pressure
 

"Martin" wrote in message
...
We have kitchen faucet that is the farthest one from the water entry point
in the house. It always has seemed to have a little lower pressure than
several others we have in the house, but recently the flow in this one has
dropped drastically. I was wondering if this might be due to something
wrong with mixing device in the faucet and whether it needs to be

replaced.

The faucet is a Kohler single hole mounting, single lever type with a pull
out spray head. The mixing cartridge is a plastic assembly with 2 O-rings
on the bottom. I can see 2 little springs inside, but the assembly

doesn't
look like it was meant to be taken apart so I couldn't check for
obstructions inside.

Is it likely that just replacing the cartridge will fix it? I've seen

them
at Home Depot and Lowes. Or should I be looking somewhere else for the
cause.

Suggestions would be appreciated.

There's probably a screen in the nozzle. Have you checked to see if it's
clogged?



spudnuty January 4th 06 06:31 AM

Kitchen faucet losing pressure
 

gib wrote:
"Martin" wrote in message
...
We have kitchen faucet that is the farthest one from the water entry point
in the house. It always has seemed to have a little lower pressure than
several others we have in the house, but recently the flow in this one has
dropped drastically. I was wondering if this might be due to something
wrong with mixing device in the faucet and whether it needs to be

replaced.

The faucet is a Kohler single hole mounting, single lever type with a pull
out spray head. The mixing cartridge is a plastic assembly with 2 O-rings
on the bottom. I can see 2 little springs inside, but the assembly

doesn't
look like it was meant to be taken apart so I couldn't check for
obstructions inside.

Is it likely that just replacing the cartridge will fix it? I've seen

them
at Home Depot and Lowes. Or should I be looking somewhere else for the
cause.

Suggestions would be appreciated.

There's probably a screen in the nozzle. Have you checked to see if it's
clogged?

There can sometimes be screens in the inlet pipes, also. Disconnect the
flex there and check. You can also check your water pressure at that
point. Use a bucket. If there's pressure and nothing in the screens
then pull the cartridge. Actually looks like you already did that.
Check the pressure with the cartridge out. Put the bucket over the open
faucet this time. Good, replace the cartridge. Bad, look for inlet
screens.
Richard


buffalobill January 4th 06 07:04 AM

Kitchen faucet losing pressure
 
to determine how successful you are, write down how many seconds does
it take to get a gallon of hot? cold? warm?

you could open up the fixture and flush out the fixture, flush out the
debris in stop valves below by opening and closing them with the water
running thru them.

here's a trick i used once:
if debris is blocking the sink hot, block the sink aerator, close
supply to water heater, open hot at the basement washtub, open the
fixture to full warm, and backflush the cold thru to basement washtub.
no improvement? swap instructions and backflush other line.
no improvement?
find all valve stops between main and the problem sink. remove and
replace debris inside and replace their broken and disintegrated rubber
washers blocking the line.
if you are still using old galvanized silver colored pipes, the
reduction of the inside diameter causing a restriction in flow is a
regular battle until replacement.

to determine how successful you were, write down how many seconds does
it take to get a gallon of hot? cold? warm?


philkryder January 4th 06 09:14 AM

Kitchen faucet losing pressure
 

buffalobill wrote:
to determine how successful you are, write down how many seconds does
it take to get a gallon of hot? cold? warm?

you could open up the fixture and flush out the fixture, flush out the
debris in stop valves below by opening and closing them with the water
running thru them.

here's a trick i used once:
if debris is blocking the sink hot, block the sink aerator, close
supply to water heater, open hot at the basement washtub, open the
fixture to full warm, and backflush the cold thru to basement washtub.
no improvement? swap instructions and backflush other line.
no improvement?
find all valve stops between main and the problem sink. remove and
replace debris inside and replace their broken and disintegrated rubber
washers blocking the line.
if you are still using old galvanized silver colored pipes, the
reduction of the inside diameter causing a restriction in flow is a
regular battle until replacement.

to determine how successful you were, write down how many seconds does
it take to get a gallon of hot? cold? warm?



philkryder January 4th 06 09:15 AM

Kitchen faucet losing pressure
 
Wow - that method takes me back.
I had a watersoftener spew its resin into the water lines.
I used the technique that you describe to clear them...

buffalobill wrote:
to determine how successful you are, write down how many seconds does
it take to get a gallon of hot? cold? warm?

you could open up the fixture and flush out the fixture, flush out the
debris in stop valves below by opening and closing them with the water
running thru them.

here's a trick i used once:
if debris is blocking the sink hot, block the sink aerator, close
supply to water heater, open hot at the basement washtub, open the
fixture to full warm, and backflush the cold thru to basement washtub.
no improvement? swap instructions and backflush other line.
no improvement?
find all valve stops between main and the problem sink. remove and
replace debris inside and replace their broken and disintegrated rubber
washers blocking the line.
if you are still using old galvanized silver colored pipes, the
reduction of the inside diameter causing a restriction in flow is a
regular battle until replacement.

to determine how successful you were, write down how many seconds does
it take to get a gallon of hot? cold? warm?



Martin January 4th 06 07:21 PM

Kitchen faucet losing pressure
 
Thanks all for the suggestions. I decided to take the spray head apart.
It was really full of junk, looked like ground up rubber washers.
Surprising since there was a good screen at the end of the attached hose.
Cleaned it out and we have lottsa pressure now.


"buffalobill" wrote in message
oups.com...
to determine how successful you are, write down how many seconds does
it take to get a gallon of hot? cold? warm?

you could open up the fixture and flush out the fixture, flush out the
debris in stop valves below by opening and closing them with the water
running thru them.

here's a trick i used once:
if debris is blocking the sink hot, block the sink aerator, close
supply to water heater, open hot at the basement washtub, open the
fixture to full warm, and backflush the cold thru to basement washtub.
no improvement? swap instructions and backflush other line.
no improvement?
find all valve stops between main and the problem sink. remove and
replace debris inside and replace their broken and disintegrated rubber
washers blocking the line.
if you are still using old galvanized silver colored pipes, the
reduction of the inside diameter causing a restriction in flow is a
regular battle until replacement.

to determine how successful you were, write down how many seconds does
it take to get a gallon of hot? cold? warm?





All times are GMT +1. The time now is 11:56 AM.