  #1   Report Post  
 
Posts: n/a
Default copper fittings for use with a pressure gage

Hello,
I am looking for a fitting that will allow be to have a pressure gauge
near the inlet of my city water so I can always see what my pressure
is. I live on a hill near the water tank and our home pressure runs
about 40 psi most times. I would need a tee fitting that I could cut
into the 3/4" copper piping to allow the water through with a port for
the pressure gauge I have [Merrill PG100 with a 1/4" male thread]
Does such a beast exist or am I going to have to build something up
with brass fittings?



|
|
|----gauge Merrill PG100 with a 1/4" male thread
|
|

^
|
water direction

Thanks!
ayb

  #2   Report Post  
Toller
 
Posts: n/a
Default

I just stick mine on the drain of the water heater.


  #3   Report Post  
Greg O
 
Posts: n/a
Default

wrote in message
ups.com...
Hello,
I am looking for a fitting that will allow be to have a pressure gauge
near the inlet of my city water so I can always see what my pressure
is. I live on a hill near the water tank and our home pressure runs
about 40 psi most times. I would need a tee fitting that I could cut
into the 3/4" copper piping to allow the water through with a port for
the pressure gauge I have [Merrill PG100 with a 1/4" male thread]
Does such a beast exist or am I going to have to build something up
with brass fittings?



Hard to tell what is available in your area, but you should be able to find
a 3/4" sweat tee, with a female thread that you can bush down to the gauge.
If nothing else a 3/4" tee, with a female NPT adapter soldered to it.
Greg


  #6   Report Post  
Richard J Kinch
 
Posts: n/a
Default

Duane Bozarth writes:

Gages are pretty unreliable, especially when under pressure all the
time.


???? A device designed specifically for the purpose is unreliable???


Absolutely. This is the nature of the Bourdon tube mechanism.
  #7   Report Post  
Edwin Pawlowski
 
Posts: n/a
Default


"Richard J Kinch" wrote in message
. ..
Duane Bozarth writes:

Gages are pretty unreliable, especially when under pressure all the
time.


???? A device designed specifically for the purpose is unreliable???


Absolutely. This is the nature of the Bourdon tube mechanism.


Can you quantify "unreliable'? Will they stick in one spot,? Not go up?
Not come down? Read high? Read low? All of the above?


  #8   Report Post  
Duane Bozarth
 
Posts: n/a
Default

Richard J Kinch wrote:

Duane Bozarth writes:

Gages are pretty unreliable, especially when under pressure all the
time.


???? A device designed specifically for the purpose is unreliable???


Absolutely. This is the nature of the Bourdon tube mechanism.


Many other ways of building them...

Ones one the system here last for several years at least and then it's
rarely the gauge itself that fails, it's accumulated rust/sediment.

Units work in power plants for years as well...but, of course, they're
industrial units.
  #9   Report Post  
Richard J Kinch
 
Posts: n/a
Default

Edwin Pawlowski writes:

Absolutely. This is the nature of the Bourdon tube mechanism.


Can you quantify "unreliable'? Will they stick in one spot,? Not go
up? Not come down? Read high? Read low? All of the above?


All of the above are typical except perhaps reading high.

The least bit of corrosion from a wet or condensing environment will spoil
the little gears and bearings.

If you ever have a bad one to throw out, tear it apart and have a look.
Looks like the proverbial ladies watch.

Here's a pretty good explanation and diagram:

http://www.tpub.com/content/fc/14104/css/14104_232.htm
  #11   Report Post  
z
 
Posts: n/a
Default


Richard J Kinch wrote:
Edwin Pawlowski writes:

Absolutely. This is the nature of the Bourdon tube mechanism.


Can you quantify "unreliable'? Will they stick in one spot,? Not go
up? Not come down? Read high? Read low? All of the above?


All of the above are typical except perhaps reading high.

The least bit of corrosion from a wet or condensing environment will spoil
the little gears and bearings.

If you ever have a bad one to throw out, tear it apart and have a look.
Looks like the proverbial ladies watch.

Here's a pretty good explanation and diagram:

http://www.tpub.com/content/fc/14104/css/14104_232.htm


Mm. Time to go back to the mercury manometer.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
type of copper to use to repipe house Ron Home Repair 42 February 9th 05 04:59 PM
trenching and other uses of a high pressure washer Jer Home Repair 5 November 18th 04 09:59 PM
ATX Power supply - defective fuse? RubbishRat Electronics Repair 2 July 23rd 04 12:38 PM
Determining Geologic Sources of Native American Copper Yuri Kuchinsky Metalworking 92 June 23rd 04 06:21 PM
Purity of copper when you melt it Zipper Metalworking 5 October 8th 03 07:12 PM