Home Ownership (misc.consumers.house)

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to misc.consumers.house
external usenet poster
 
Posts: 2
Default Water leak

I have had three water leaks in my home in the last three months. I am
wondering what is the problem. The leaks have gone from one side of
the house to the other. Is the plumber taking me for a ride or is it
worn pipes? I know my insurance company is going to drop us with the
next claim. Will it be cheaper to just go ahead and replace the pipes
than continiously filing claims and paying the deductible? The house
is 13 years old and we have been living in Coastal Georgia for 15
months. There has been no other problems with leaks until now. The
inspector did not detect any leaks. It seems to be a problem in this
area from what we have heard after we bought our house of course. Need
answers.

  #2   Report Post  
Posted to misc.consumers.house
external usenet poster
 
Posts: 222
Default Water leak

In article .com,
"FIXITPLS" wrote:

I have had three water leaks in my home in the last three months. I am
wondering what is the problem. The leaks have gone from one side of
the house to the other. Is the plumber taking me for a ride or is it
worn pipes? I know my insurance company is going to drop us with the
next claim. Will it be cheaper to just go ahead and replace the pipes
than continiously filing claims and paying the deductible? The house
is 13 years old and we have been living in Coastal Georgia for 15
months. There has been no other problems with leaks until now. The
inspector did not detect any leaks. It seems to be a problem in this
area from what we have heard after we bought our house of course. Need
answers.


Did the plumber explain the leaks to you? Were they actual pipes,
or was it joints, fittings, or fixtures? Are you on city water
or are you on your own private well or community water system?
Copper or lead or other type of plumbing? Have you had your
water tested?

While I have no information from you to give any advice, I can
relate a similar problem that I have seen in central Wisconsin.
The water in some locations there has a low PH number. As a
result, it reacts with copper over time, and puts many tiny
pinholes in the copper. You fix it in one place, and another
place a few feet down will leak. These people were able to
install a neutralizer, which stopped the deterioration. But
at that point, it was too late, and much of the copper had
to be replaced. The small line to the ice maker had leaked
a few times before the bigger 1/2 inch copper leaked, so that
was their clue that something was wrong.

-john-

--
================================================== ====================
John A. Weeks III 952-432-2708
Newave Communications
http://www.johnweeks.com
================================================== ====================
  #3   Report Post  
Posted to misc.consumers.house
external usenet poster
 
Posts: 4,500
Default Water leak


John A. Weeks III wrote:
In article .com,
"FIXITPLS" wrote:

I have had three water leaks in my home in the last three months. I am
wondering what is the problem. The leaks have gone from one side of
the house to the other. Is the plumber taking me for a ride or is it
worn pipes? I know my insurance company is going to drop us with the
next claim. Will it be cheaper to just go ahead and replace the pipes
than continiously filing claims and paying the deductible? The house
is 13 years old and we have been living in Coastal Georgia for 15
months. There has been no other problems with leaks until now. The
inspector did not detect any leaks. It seems to be a problem in this
area from what we have heard after we bought our house of course. Need
answers.


Did the plumber explain the leaks to you? Were they actual pipes,
or was it joints, fittings, or fixtures? Are you on city water
or are you on your own private well or community water system?
Copper or lead or other type of plumbing? Have you had your
water tested?

While I have no information from you to give any advice, I can
relate a similar problem that I have seen in central Wisconsin.
The water in some locations there has a low PH number. As a
result, it reacts with copper over time, and puts many tiny
pinholes in the copper. You fix it in one place, and another
place a few feet down will leak. These people were able to
install a neutralizer, which stopped the deterioration. But
at that point, it was too late, and much of the copper had
to be replaced. The small line to the ice maker had leaked
a few times before the bigger 1/2 inch copper leaked, so that
was their clue that something was wrong.

-john-

--
================================================== ====================
John A. Weeks III 952-432-2708
Newave Communications
http://www.johnweeks.com
================================================== ====================



To the above, I would add, we don't even know if it's water supply line
leaks, sewer pipe leaks, or a combo.

  #4   Report Post  
Posted to misc.consumers.house
external usenet poster
 
Posts: 2
Default Water leak

My husband talked with the plumber and as I understand it, this is a
problem that they have in this area with the water and algae. They have
even suggested that we pour bleach down our drains every few months.
This sounds like something that would eat up the pipes like it would
eat up everything else. I saw a small piece of the pipes they replaced
and it looks all corrodide and rusted. Lets put it this way, that
piece didnt look good all all. I hate to see the rest of the pipes.
Of course I know nothing about plumbing. The plumber says it is best
to re-route new pipes though the roof. We are on city water. We have
not had our water tested. Is it best to go with the plastic pipes
(PVC?) or use copper? Once we do install the new pipes should we also
add the neutralizer? The whole thing is giving me a headache. I need
to make the correct decision now to prevent this from happening 13 more
years down the line. Thanks for your help.
John A. Weeks III wrote:
In article .com,
"FIXITPLS" wrote:

I have had three water leaks in my home in the last three months. I am
wondering what is the problem. The leaks have gone from one side of
the house to the other. Is the plumber taking me for a ride or is it
worn pipes? I know my insurance company is going to drop us with the
next claim. Will it be cheaper to just go ahead and replace the pipes
than continiously filing claims and paying the deductible? The house
is 13 years old and we have been living in Coastal Georgia for 15
months. There has been no other problems with leaks until now. The
inspector did not detect any leaks. It seems to be a problem in this
area from what we have heard after we bought our house of course. Need
answers.


Did the plumber explain the leaks to you? Were they actual pipes,
or was it joints, fittings, or fixtures? Are you on city water
or are you on your own private well or community water system?
Copper or lead or other type of plumbing? Have you had your
water tested?

While I have no information from you to give any advice, I can
relate a similar problem that I have seen in central Wisconsin.
The water in some locations there has a low PH number. As a
result, it reacts with copper over time, and puts many tiny
pinholes in the copper. You fix it in one place, and another
place a few feet down will leak. These people were able to
install a neutralizer, which stopped the deterioration. But
at that point, it was too late, and much of the copper had
to be replaced. The small line to the ice maker had leaked
a few times before the bigger 1/2 inch copper leaked, so that
was their clue that something was wrong.

-john-

--
================================================== ====================
John A. Weeks III 952-432-2708
Newave Communications
http://www.johnweeks.com
================================================== ====================


  #5   Report Post  
Posted to misc.consumers.house
external usenet poster
 
Posts: 222
Default Water leak

In article . com,
"FIXITPLS" wrote:

My husband talked with the plumber and as I understand it, this is a
problem that they have in this area with the water and algae. They have
even suggested that we pour bleach down our drains every few months.
This sounds like something that would eat up the pipes like it would
eat up everything else. I saw a small piece of the pipes they replaced
and it looks all corrodide and rusted. Lets put it this way, that
piece didnt look good all all. I hate to see the rest of the pipes.
Of course I know nothing about plumbing. The plumber says it is best
to re-route new pipes though the roof. We are on city water. We have
not had our water tested. Is it best to go with the plastic pipes
(PVC?) or use copper? Once we do install the new pipes should we also
add the neutralizer? The whole thing is giving me a headache. I need
to make the correct decision now to prevent this from happening 13 more
years down the line. Thanks for your help.


I don't know if PVC is legal in your area. I would suggest using
PEX plumbing, which is new on the market in the US, but has a long
track record in Europe. It is flexiable, very resistant, and
goes together with crimp connectors. It should last in this
situation.

You still want to get a water filter and treatment system. Not
only will it improve the water taste and smell, but it will keep
some of the bad stuff out of your body, it will let detergent
work better, and it will be far easier on your clothes in the
wash. You will probably save more in clothing than what the
system would cost to install.

-john-

--
================================================== ====================
John A. Weeks III 952-432-2708
Newave Communications
http://www.johnweeks.com
================================================== ====================


  #6   Report Post  
Posted to misc.consumers.house
external usenet poster
 
Posts: 455
Default Water leak

"John A. Weeks III" wrote:


I don't know if PVC is legal in your area. I would suggest using
PEX plumbing, which is new on the market in the US, but has a long
track record in Europe. It is flexiable, very resistant, and
goes together with crimp connectors. It should last in this
situation.


PEX is not new in the US, its been around since the 70s. Google on Shell and PEX
for details of a particularly nasty lawsuit or click he
http://www.paccrestinspections.com/polybutylene.htm

That said, the current PEX formulations are probably fine...
  #7   Report Post  
Posted to misc.consumers.house
external usenet poster
 
Posts: 455
Default Water leak

Rick Blaine wrote:

PEX is not new in the US, its been around since the 70s. Google on Shell and PEX
for details of a particularly nasty lawsuit or click he
http://www.paccrestinspections.com/polybutylene.htm

That said, the current PEX formulations are probably fine...


Whoops. Confused PEX and PB. Never mind (in Lilly Thompson voice).
  #8   Report Post  
Posted to misc.consumers.house
external usenet poster
 
Posts: 455
Default Water leak

Rick Blaine wrote:

Never mind (in Lilly Thompson voice).


Sigh. Lily Tomlin.

Knew I shouldn't have had the second glass of wine with dinner.
  #9   Report Post  
Posted to misc.consumers.house
external usenet poster
 
Posts: 509
Default Water leak

Rick Blaine writes:

Rick Blaine wrote:

Never mind (in Lilly Thompson voice).


Sigh. Lily Tomlin.

Knew I shouldn't have had the second glass of wine with dinner.


I may make you sigh some more though.

Wasn't the "Never mind" bit Gilda Radner's (as Emily Litella)?
http://en.wikipedia.org/wiki/Emily_Litella

"What is this I hear about endangered feces?"

Best Regards,
--
Todd H.
http://www.toddh.net/
  #10   Report Post  
Posted to misc.consumers.house
external usenet poster
 
Posts: 455
Default Water leak

(Todd H.) wrote:


I may make you sigh some more though.

Wasn't the "Never mind" bit Gilda Radner's (as Emily Litella)?
http://en.wikipedia.org/wiki/Emily_Litella

"What is this I hear about endangered feces?"


Never mind.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Help ! Water Heater Leak ! [email protected] Home Repair 13 September 14th 06 10:40 PM
Hot Water Recirculator Comfort Valve Inefficiencies Cost More Then An Outlet Install [email protected] Home Repair 0 April 21st 06 12:13 AM
Leak in hot water tank Johnny UK diy 9 April 9th 04 07:28 PM
NO MORE hot water problems [email protected] Home Repair 9 January 29th 04 06:15 PM
Thankless or Tankless hot water heaters [email protected] Home Repair 6 January 29th 04 03:01 AM


All times are GMT +1. The time now is 07:32 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"