Bob F October 28th 06 11:46 PM

hot water heater leak and tankless water heater?
 

"THO" wrote in message
...
It looks like I may need a new hot water heater. We lost hot water and
when I checked it out, there was water dripping from the emergency
release valve and a large amount of water on the floor (but less than
when the 2nd hot water heater died). The pilot was out also.


If all the leakage came from the safety valve, you might have a
repairable problem. The valve, expansion tank, regulator could
be looked at. Did the leakage from the safety valve put out the
pilot?

Bob



briz October 29th 06 12:40 PM

hot water heater leak and tankless water heater?
 

With out looking at your water heater any advise on what the problem
might be is only a guess. however I do have experience with the
tankless water heaters.
When I built my new home in N.Florida I installed a tankless LP gas
water heater. Love it! Unlimited hot water and very cheep to run. I got
the 9.3 GPM heater becouse of the size of the house # of baths (3.5)
and dishwasher washer ect.I can shower have the kids run the bath
water and do laundry at the same time and have enough water. It was
expencive up front, 900.00, but the savings in the long run will pay
off. Also as a bonus, It is the size of a very small suitcase and
mounted on the outside of the house. No huge tank to store hot water
untill you might need it!
My mom bought a new house and had it set near by my home and first
thing we did was take out the tank style water heater and put in a 4
GPM electric tankless heater. this one was even smaller, cost less and
ave her a new closet to hang coats in. her Highest power bill this
summer was 80.00 in FL.!!!! unlimited hot water on demand! Tankless Is
the wat to go! I got both on Ebay!


[email protected] October 29th 06 02:09 PM

hot water heater leak and tankless water heater?
 

tankless poor choice in many areas


Al October 29th 06 02:43 PM

hot water heater leak and tankless water heater?
 
WHY? Can you be more specific?
wrote in message
ups.com...

tankless poor choice in many areas




[email protected] October 29th 06 02:54 PM

hot water heater leak and tankless water heater?
 
The wind blowing the pilot light out would not cause water to be
released from the relief valve. One big question here is how old is
the unit? If it's older than 10 years, and depending on where it's
located, I wouldn't even fool around with it. Somewhere around 13
years or so is the typical life expectancy. And if it's located where
if it suddenly starts leaking, it's going to do big damage, I'd just
replace it.

As for the tankless, one big consideration in an apartment is whether
you have a gas line large enough to support it. If you don't, you may
not be able to install it at all, unless the building allows the work
and your willing to pay for it.


[email protected] October 29th 06 03:12 PM

hot water heater leak and tankless water heater?
 

Al wrote:
WHY? Can you be more specific?
wrote in message
ups.com...

tankless poor choice in many areas


Cost of tank including new gas line, electric outlet and possibly Flue
will likely exceed the energy saved over the life of the tank.

tasnkless only warranteed for 10 years, regular tanks last about that
long.

so as a example a tankless for $1200 or a regular tank for $400 their
warranty life about the same.

That means that you would need to save 800 bucks on gas over the life
of the tank before you save one cent in actual costs. to pay back the
initial investment.

Now in regular tanks today the foam insulation makes standby losses
low, I have turned off a tank and had a nice hot shower a day later.
while doing some remodeling here.

If your tank lives indoors in a part of the country that needs heat in
the winter the stanby losses help heat your home so they really arent
losses at all for maybe 1/2 the year.....

so double your tankless payback period.

now the fellow who loves his tankless... sounds like he lves in florida
where oudoor temps dont freeze hard in the winter.

A tankless in the summer may work fine, when the incoming water temp is
65 degrees, in the winter with incoming at 40 degrees showers may be
shiver sessions.


Bob F October 29th 06 05:50 PM

hot water heater leak and tankless water heater?
 

"THO" wrote in message
...
In article . com,
wrote:

The wind blowing the pilot light out would not cause water to be
released from the relief valve. One big question here is how old is
the unit? If it's older than 10 years, and depending on where it's


Try not to laugh ... its a copper tank model that is 24 years old. :)

I hate to see it go. We just replaced the 2nd floor heater 6 years after
installation and it was out of warranty.


It sounds like it should be worth figuring out the problem and fixing
it. If it's just leaking out the safety valve, and it is not likely to be
the tank that is the problem. Maybe the safety valve, thermostat,
regulator, expansion tank, etc.

Bob



Bob M. October 29th 06 09:38 PM

hot water heater leak and tankless water heater?
 

"THO" wrote in message
...
In article . com,
wrote:

The wind blowing the pilot light out would not cause water to be
released from the relief valve. One big question here is how old is
the unit? If it's older than 10 years, and depending on where it's


Try not to laugh ... its a copper tank model that is 24 years old. :)



A copper tank is worth keeping IMO. Mine is a glass-lined steel tank and
it's going on 28 years old. Replace the anode every couple of years and
you'll go well beyond the usual lifetime of a steel tank.

It's kind of annoying to hear people say "they only last 10-15years anyhow"
when the problems leading to such a short life are easily and cheaply
fixable. (drain the tank yearly to get rid of sediment and check/replace the
anode every few years)



[email protected] October 30th 06 12:28 PM

hot water heater leak and tankless water heater?
 

Bob M. wrote:
"THO" wrote in message
...
In article . com,
wrote:

The wind blowing the pilot light out would not cause water to be
released from the relief valve. One big question here is how old is
the unit? If it's older than 10 years, and depending on where it's


Try not to laugh ... its a copper tank model that is 24 years old. :)



A copper tank is worth keeping IMO. Mine is a glass-lined steel tank and
it's going on 28 years old. Replace the anode every couple of years and
you'll go well beyond the usual lifetime of a steel tank.

It's kind of annoying to hear people say "they only last 10-15years anyhow"
when the problems leading to such a short life are easily and cheaply
fixable. (drain the tank yearly to get rid of sediment and check/replace the
anode every few years)




Sorry to annoy you, but the simple fact is 10-15 years is a typical
lifespan for gas water heaters. And, IMO, depending on where the tank
is located, anyone trying to push the lifespan of one of these is
foolish. Sure, inspecting and changing the anode is a good idea. The
difference is, I look at that as a way to get to 13 years with some
extra safety margin, not a way to extend the life indefinitely, which
it cannot do. And when they go, the failure can be sudden and
depending on where it's located, catastrophic. Would you rather have a
bill for $500 for replacing a 13 year old heater, or a bill for $10K in
damages caused by a water heater that suddenly starts spewing water?


Bob F October 30th 06 10:05 PM

hot water heater leak and tankless water heater?
 

wrote in message
Sorry to annoy you, but the simple fact is 10-15 years is a typical
lifespan for gas water heaters. And, IMO, depending on where the tank
is located, anyone trying to push the lifespan of one of these is
foolish. Sure, inspecting and changing the anode is a good idea. The
difference is, I look at that as a way to get to 13 years with some
extra safety margin, not a way to extend the life indefinitely, which
it cannot do. And when they go, the failure can be sudden and
depending on where it's located, catastrophic. Would you rather have a
bill for $500 for replacing a 13 year old heater, or a bill for $10K in
damages caused by a water heater that suddenly starts spewing water?


And of course, all water heaters can be expected to last the same time,
no matter what the water is like, or what the heater is made of.

Bob



kyle york October 31st 06 05:55 PM

hot water heater leak and tankless water heater?
 
Greetings,

Al wrote:
WHY? Can you be more specific?


Around here where every few years we lose water for a day or so it's
nice to have 50 gallons of fresh water always available.

Also, don't forget the opportunity cost of the money when determining
payback. Folks tend to forgot about that.

--
Kyle A. York
Sr. Subordinate Grunt
DSBU

Bob M. November 1st 06 03:44 AM

hot water heater leak and tankless water heater?
 

wrote in message
oups.com...

Bob M. wrote:
"THO" wrote in message
...
In article . com,
wrote:

The wind blowing the pilot light out would not cause water to be
released from the relief valve. One big question here is how old is
the unit? If it's older than 10 years, and depending on where it's

Try not to laugh ... its a copper tank model that is 24 years old. :)



A copper tank is worth keeping IMO. Mine is a glass-lined steel tank and
it's going on 28 years old. Replace the anode every couple of years and
you'll go well beyond the usual lifetime of a steel tank.

It's kind of annoying to hear people say "they only last 10-15years
anyhow"
when the problems leading to such a short life are easily and cheaply
fixable. (drain the tank yearly to get rid of sediment and check/replace
the
anode every few years)




Sorry to annoy you, but the simple fact is 10-15 years is a typical
lifespan for gas water heaters. And, IMO, depending on where the tank
is located, anyone trying to push the lifespan of one of these is
foolish. Sure, inspecting and changing the anode is a good idea. The
difference is, I look at that as a way to get to 13 years with some
extra safety margin, not a way to extend the life indefinitely, which
it cannot do. And when they go, the failure can be sudden and
depending on where it's located, catastrophic. Would you rather have a
bill for $500 for replacing a 13 year old heater, or a bill for $10K in
damages caused by a water heater that suddenly starts spewing water?




10-15 years is the average only because people aren't checking the things
that can be checked & fixed easily.