Zenith Flyback...generic replacement
Does anyone recall anything concerning a shutdown problem after replacing a
Zenith flyback with a generic? I have a SL2784BT using a 9-1268 sweep board that will shutdown after about 20 seconds. Turning the set back on causes the cycle to repeat. I used a generic fly from Tritronics. Thanks! |
I had the same problem with a Hitachi set. After some hours of
searching, it turned out to be a leaky capacitor between the collector and the emitter of the H.O.Transistor (.39 mfd at 1.6 KV). It caused the emitter voltage to rise slowly and then turn on the shutdown circuit. Thomas Abell wrote: Does anyone recall anything concerning a shutdown problem after replacing a Zenith flyback with a generic? I have a SL2784BT using a 9-1268 sweep board that will shutdown after about 20 seconds. Turning the set back on causes the cycle to repeat. I used a generic fly from Tritronics. Thanks! |
All times are GMT +1. The time now is 02:29 PM. |
Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.