PC-controlled multimeter
I'm looking for recommendations on a computer-controlled multimeter to automate a test procedure. I'd like to be able to have the computer select voltage, resistance, etc., choose various ranges in each, and transmit readings to a PC. I see a lot of units that communicate, but I'm unclear whether they allow functions and ranges to be set, or whether they just transmit results from the range selected on the front dial. The one unusual requirement is a high resistance range (e.g. 2000Mohm). ACV/DCV/ohms ranges can otherwise be similar to regular handheld units. Any suggestions? |
#2
Posted to sci.electronics.design,sci.electronics.equipment,sci.electronics.repair
|
|||
|
|||
PC-controlled multimeter
On Sat, 23 Jun 2018 11:22:06 -0600, Randy Day
wrote: I'm looking for recommendations on a computer-controlled multimeter to automate a test procedure. I'd like to be able to have the computer select voltage, resistance, etc., choose various ranges in each, and transmit readings to a PC. I see a lot of units that communicate, but I'm unclear whether they allow functions and ranges to be set, or whether they just transmit results from the range selected on the front dial. The one unusual requirement is a high resistance range (e.g. 2000Mohm). ACV/DCV/ohms ranges can otherwise be similar to regular handheld units. Any suggestions? We use a lot of Keithley and Fluke benchtop DVMs in test sets, with ethernet or USB interface. They can set anything under remote control except for switching between the front and rear-panel inputs. I prefer the Fluke 8845A. It's more stable at microvolt levels, does good AC measurements, and is EMI harder than the Keithleys. It only measures 100M ohms max, but you could do some simple hack to measure gigohms. There are cheap handhelds with interfaces, but the interface won't turn the big range knob. There are also cheap benchtop DVMs, typically Chinese. Might be good enough. -- John Larkin Highland Technology, Inc lunatic fringe electronics |
#3
Posted to sci.electronics.design,sci.electronics.equipment,sci.electronics.repair
|
|||
|
|||
PC-controlled multimeter
Am 23.06.2018 um 19:22 schrieb Randy Day:
I'm looking for recommendations on a computer-controlled multimeter to automate a test procedure. I'd like to be able to have the computer select voltage, resistance, etc., choose various ranges in each, and transmit readings to a PC. I see a lot of units that communicate, but I'm unclear whether they allow functions and ranges to be set, or whether they just transmit results from the range selected on the front dial. The one unusual requirement is a high resistance range (e.g. 2000Mohm). ACV/DCV/ohms ranges can otherwise be similar to regular handheld units. Any suggestions? Here https://www-user.tu-chemnitz.de/~heha/hs/UNI-T/ are some programs for UNI-T or similar multimeters. peter |
#4
Posted to sci.electronics.design,sci.electronics.equipment,sci.electronics.repair
|
|||
|
|||
PC-controlled multimeter
On 2018/06/23 10:22 AM, Randy Day wrote:
I'm looking for recommendations on a computer-controlled multimeter to automate a test procedure. I'd like to be able to have the computer select voltage, resistance, etc., choose various ranges in each, and transmit readings to a PC. I see a lot of units that communicate, but I'm unclear whether they allow functions and ranges to be set, or whether they just transmit results from the range selected on the front dial. The one unusual requirement is a high resistance range (e.g. 2000Mohm). ACV/DCV/ohms ranges can otherwise be similar to regular handheld units. Any suggestions? Mooshimeter? Doesn't do resistance, but for remote monitoring of voltage and current it is handy...and perhaps the designer is interested in expanding it to resistance. https://moosh.im/mooshimeter/ Handy tool! John :-#)# -- (Please post followups or tech inquiries to the USENET newsgroup) John's Jukes Ltd. MOVED to #7 - 3979 Marine Way, Burnaby, BC, Canada V5J 5E3 (604)872-5757 (Pinballs, Jukes, Video Games) www.flippers.com "Old pinballers never die, they just flip out." |
#6
Posted to sci.electronics.design,sci.electronics.equipment,sci.electronics.repair
|
|||
|
|||
PC-controlled multimeter
|
#7
Posted to sci.electronics.repair
|
|||
|
|||
PC-controlled multimeter
Yep, Fluke, Keysight (formerly Agilent/HP) and Keithley which is now Tek or Tektronix are like the goto options.
These http://www.ni.com/pdf/product-flyers...ultimeters.pdf may prove to be a unique addition. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Temperature Controlled Furnace? | Metalworking | |||
Computer controlled wood milling machine - advice required | UK diy | |||
low voltage PIR controlled lights for drive - where? | UK diy | |||
Dimmer switch on a ceilling fan controlled at one wall switch | Metalworking | |||
Radio controlled clock question | UK diy |