BIOS date and time in a Pentium 4 not adjustable.
A Pentium 4 with Intel system board here.
When powered up the screen displays GB85010A.86A.0078.P18.0110081719 ... CMOS Battery Low CMOS Date/Time Not Set No response to any keys when attempting to adjust date and time. No problem changing other BIOS parameters. This is only to prevent the user from adjusting the clock when it can't keep time with power off? A failure in the BIOS? Thanks, ... Peter E. |
#2
Posted to sci.electronics.repair
|
|||
|
|||
BIOS date and time in a Pentium 4 not adjustable.
Change the battery. It is possible that the low battery condition is preventing any further action.
Dan |
#3
Posted to sci.electronics.repair
|
|||
|
|||
BIOS date and time in a Pentium 4 not adjustable.
The parameters of the BIOS are grooved in a Flash memory
THe date/time comes from a clock circuit ; it needs a higher minimum voltage for operate Peter Easthope a écrit : A Pentium 4 with Intel system board here. When powered up the screen displays GB85010A.86A.0078.P18.0110081719 ... CMOS Battery Low CMOS Date/Time Not Set No response to any keys when attempting to adjust date and time. No problem changing other BIOS parameters. This is only to prevent the user from adjusting the clock when it can't keep time with power off? A failure in the BIOS? Thanks, ... Peter E. |
#4
Posted to sci.electronics.repair
|
|||
|
|||
BIOS date and time in a Pentium 4 not adjustable.
On 04/02/17 03:24, Peter Easthope wrote:
A Pentium 4 with Intel system board here. When powered up the screen displays GB85010A.86A.0078.P18.0110081719 ... CMOS Battery Low CMOS Date/Time Not Set No response to any keys when attempting to adjust date and time. Check the onscreen instructions carefully (normally on the bottom row) on what keys to press to change item values. Sometimes it's F5/F6, sometimes something else like direct entry (guess you tried that). -- Adrian C |
#6
Posted to sci.electronics.repair
|
|||
|
|||
BIOS date and time in a Pentium 4 not adjustable.
"Andrew Rossmann" wrote in message ... In article , says... A Pentium 4 with Intel system board here. When powered up the screen displays GB85010A.86A.0078.P18.0110081719 ... CMOS Battery Low CMOS Date/Time Not Set No response to any keys when attempting to adjust date and time. No problem changing other BIOS parameters. This is only to prevent the user from adjusting the clock when it can't keep time with power off? A failure in the BIOS? Thanks, ... Peter E. As others mentioned, you probably need to replace the battery first. It may be blocked due to that. The most common battery is a CR2032, although you can possibly use a CR2025 or CR2016 in a pinch if you happen to have one. The only difference is the thickness. 3.2mm, 2.5mm, 1.6mm. Some of those older boards had a potted module with a 0.6" chip form factor. IIRC: it was a Dallas RTC chip (which may have been more or less compatible with the original Motorola chipset RTC). That had a couple of lithium coin cells stuck on top and potted. |
#7
Posted to sci.electronics.repair
|
|||
|
|||
BIOS date and time in a Pentium 4 not adjustable.
Thanks for the replies.
Dan wrote, Change the battery. Replaced the CR2032 cell with one fresh out of the package. No change in BIOS behaviour. Date and time still not changeable. Adrian wrote, Check the onscreen instructions carefully ... Photo of the screen here. http://easthope.ca/IntelD850GBClockSetting.jpg Tried +/-, Page Up/Page Down. Keyboard works otherwise. Bender wrote, Some of those older boards had a potted module with a 0.6" chip form factor. IIRC: it was a Dallas RTC chip (which may have been more or less compatible with the original Motorola chipset RTC). That had a couple of lithium coin cells stuck on top and potted. Photo of the lower left part of the board here. http://easthope.ca/IntelD850GBboard.jpg As clear possible with this camera and without losing image size. I recognize only the one lithium cell. Retrieved the Intel BIOS updater and updated. The latest version available is the same as the extant version. No problem reported in the update process. Booting stops with these being the last three lines on the screen. CMOS Date/Time Not Set Press F1 to Run SETUP Network selected as first boot device for current boot There is no 8P8C connector on the system board and no Ethernet adapter installed. Nothing about network in the boot area of the BIOS configuration. The BIOS identifies the WDC drive with a bootable system as "WDC WD1200JB-00DUA3" but won't boot from it. None of the capacitors are bulged. With the capacitors installed, no leaking electrolyte visible. Replacing capacitors seems a poor investment for an uncertain return. Any further thoughts before scrapping the board? Thanks, ... Peter E. |
#8
Posted to sci.electronics.repair
|
|||
|
|||
BIOS date and time in a Pentium 4 not adjustable.
Peter Easthope wrote:
Thanks for the replies. Dan wrote, Change the battery. Replaced the CR2032 cell with one fresh out of the package. No change in BIOS behaviour. Date and time still not changeable. Adrian wrote, Check the onscreen instructions carefully ... Photo of the screen here. http://easthope.ca/IntelD850GBClockSetting.jpg Tried +/-, Page Up/Page Down. Keyboard works otherwise. Bender wrote, Some of those older boards had a potted module with a 0.6" chip form factor. IIRC: it was a Dallas RTC chip (which may have been more or less compatible with the original Motorola chipset RTC). That had a couple of lithium coin cells stuck on top and potted. Photo of the lower left part of the board here. http://easthope.ca/IntelD850GBboard.jpg As clear possible with this camera and without losing image size. I recognize only the one lithium cell. Retrieved the Intel BIOS updater and updated. The latest version available is the same as the extant version. No problem reported in the update process. Booting stops with these being the last three lines on the screen. CMOS Date/Time Not Set Press F1 to Run SETUP Network selected as first boot device for current boot There is no 8P8C connector on the system board and no Ethernet adapter installed. Nothing about network in the boot area of the BIOS configuration. The BIOS identifies the WDC drive with a bootable system as "WDC WD1200JB-00DUA3" but won't boot from it. None of the capacitors are bulged. With the capacitors installed, no leaking electrolyte visible. Replacing capacitors seems a poor investment for an uncertain return. Any further thoughts before scrapping the board? Thanks, ... Peter E. Hi Peter, Are there two pins on the motherboard that you can temporarily short that will clear the CMOS settings? -- David Farber Los Osos, CA |
#9
Posted to sci.electronics.repair
|
|||
|
|||
BIOS date and time in a Pentium 4 not adjustable.
"Peter Easthope" wrote in message ... Thanks for the replies. Dan wrote, Change the battery. Replaced the CR2032 cell with one fresh out of the package. No change in BIOS behaviour. Date and time still not changeable. What OS? - most I've seen have time and date icon on the taskbar, have you tried setting it there? |
#10
Posted to sci.electronics.repair
|
|||
|
|||
BIOS date and time in a Pentium 4 not adjustable.
Something gross !!
Are you sure that during BIOS setting, your keyboard is Numlock ? Peter Easthope a écrit : A Pentium 4 with Intel system board here. When powered up the screen displays GB85010A.86A.0078.P18.0110081719 ... CMOS Battery Low CMOS Date/Time Not Set No response to any keys when attempting to adjust date and time. No problem changing other BIOS parameters. This is only to prevent the user from adjusting the clock when it can't keep time with power off? A failure in the BIOS? Thanks, ... Peter E. |
#11
Posted to sci.electronics.repair
|
|||
|
|||
BIOS date and time in a Pentium 4 not adjustable.
David wrote,
Are there two pins on the motherboard that you can temporarily short that will clear the CMOS settings? There is a pin set J8C2; described here. http://www.intel.com/content/www/us/...000005690.html With the jumper on 2-3, a maintenance menu added in the BIOS configuration allows passwords to be cleared. No evidence of any password set but I cleared all. After that put the jumper back to the normal 1-2 position and booted again. Still could not adjust the clock but the "Save changes and proceed" option worked and the system booted. Not sure that clearing the passwords made a difference. I could have just failed to recognize how to pass the clock problem earlier. Bender wrote, What OS? - most I've seen have time and date icon on the taskbar, have you tried setting it there? Debian and antiX. Now that I see how to start the OS, will try to set the clock there. Look165 wrote, ... Numlock ? Numlock is ok. Will return to this machine February 13 or later. Appears promising now. Thanks for the help, ... Peter E. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
How to erase date/time on Panasonic cordless phone KX-TG4112C | Home Repair | |||
Panasonic KX-TG8161E Digital Cordless phone, trying to set the time and date! | UK diy | |||
Aside from being a very unique and exciting invite, it can also allowyou to set up what type of event will entail. With basic invitations it ishard to fit in everything that will take place. Typically there is only roomfor the time, date and location | Home Repair | |||
Aside from being a very unique and exciting invite, it can also allowyou to set up what type of event will entail. With basic invitations it ishard to fit in everything that will take place. Typically there is only roomfor the time, date and location | Home Repair | |||
Adjustable Bed Mattress Find a Sale on Adjustable Bed Mattresses | Home Ownership |