Have a Emerson TC2555D that has INSF . Width . Have no schmetic . Set was
DEAD . Replaced Q401 , STR30110 , C435 ,R521 , R507 , Solder R473 , R474


Some brands of STR30110 ICs do not work. For some odd reason, the output
voltage (pin 4 of the STR30110) is supposed to be 130v instead of the expected
110v. A bad new STR30110 will read 110v on pin 4 and cause low width. If this
is the case either try another brand, or try a STR30125, or 30130. Check
voltage on pin 4 to verify you are around 130v. Also make sure you used the
right value for R507 47 ohm.
Ron
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
maximum width of top hung upvc casement window without a centre support Sean UK diy 1 July 10th 04 05:42 PM
Maximum rip width for 3/4" red oak heyscott Woodworking 12 June 11th 04 01:34 PM
Newbie question - width of glue-up pieces to make table top Jim Helfer Woodworking 8 February 27th 04 10:34 PM
Adjusting groove width with table saw misalignment...? Faustino Dina Woodworking 3 November 28th 03 02:54 AM
Emerson VCRs and Manuals Steve Thomas Electronics Repair 0 November 5th 03 07:16 PM


All times are GMT +1. The time now is 06:46 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"