Hi folks,

I am cleaning out and ran across the FG 507 I posted about years ago. It
seemed a shame to toss it, so I went to work.

It is a Tektronix 2 MHz function generator with sweep and it died completely
after my old posts. Found no -20 volts and
also found a burnt resistor, blown fuse, and a blown NPN TO-3 on the back of
the mainframe. Went to work on all that
and then found that the -20 volt bus was shorted. Replaced two 6.8 uF
tantalums and the generator fired up. Worked for
a while and then it started to act up so I also replaced two more 6.8
tantalums on the +20 volt bus. All seems OK now.

The THD was out of spec. so I diddled 3 pots and it looks good. All seems
normal now.

Thanks again to all who posted about this years ago.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Tektronix FG507 Charles Electronics Repair 39 November 19th 12 06:06 AM


All times are GMT +1. The time now is 02:36 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"