Home |
Search |
Today's Posts |
|
Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
|
|||
|
|||
Problem with Siemens Gigaset 2415
Hi,
I have a Siemens Gigaset 2415 cordless phone. It seems that after I talked on the phone for about 10-15 minutes, the other side could no longer hear me while I could still hear it clearly. If I switched to another phone, everything worked fine. If I switched back to the 2415 (2400) handset, it worked for a short time. The batteries are all fully charged. Just wondering if anyone knows what could be the problem! Thank you and best regards! Cliff. |
#2
|
|||
|
|||
Problem with Siemens Gigaset 2415
A component(s) have become thermo sensitive in the transmit section, or
in the audio preamp section in the handset, or in the receive processing section in the base. The fault must be isolated. Most likely the fault is in the handset. Because of the way you are describing the fault, I doubt it is a cold solder connection. These units use high density LSI technology with multi layer boards. I doubt very much that you are even the corner service shop and even most large service centres can service this phone at the component level. You will have to send it to the authorized service centre for Siemens phones. If you consult the instruction manual, or call Siemens directly, they can advise you of the closest service rep to you. Most of the time, when these phones are sent for service, the complete circuit board or module is changed to fix them. This is most cost effective when considering the cost of the parts and labour. They only have to re-install the new board and check its calibration. When sending the phone for service, you must send the handset, power supply, and base unit. This way they can check it as a complete system. -- Greetings, Jerry Greenberg GLG Technologies GLG ============================================== WebPage http://www.zoom-one.com Electronics http://www.zoom-one.com/electron.htm Instruments http://www.zoom-one.com/glgtech.htm ============================================== "C Yeung" wrote in message ... Hi, I have a Siemens Gigaset 2415 cordless phone. It seems that after I talked on the phone for about 10-15 minutes, the other side could no longer hear me while I could still hear it clearly. If I switched to another phone, everything worked fine. If I switched back to the 2415 (2400) handset, it worked for a short time. The batteries are all fully charged. Just wondering if anyone knows what could be the problem! Thank you and best regards! Cliff. |
#3
|
|||
|
|||
Problem with Siemens Gigaset 2415
Thanks! I suspected it as well since my wife was complaining about the
batteries were getting hot after a while. I had changed them to NiMh. I will switch it to NiCd to see if it will help. If it has no improvement, I might as well get a new handset since it will cost me less to buy a new one than to send it to repair. Best regards! Cliff. "Jerry G." wrote: A component(s) have become thermo sensitive in the transmit section, or in the audio preamp section in the handset, or in the receive processing section in the base. The fault must be isolated. Most likely the fault is in the handset. Because of the way you are describing the fault, I doubt it is a cold solder connection. These units use high density LSI technology with multi layer boards. I doubt very much that you are even the corner service shop and even most large service centres can service this phone at the component level. You will have to send it to the authorized service centre for Siemens phones. If you consult the instruction manual, or call Siemens directly, they can advise you of the closest service rep to you. Most of the time, when these phones are sent for service, the complete circuit board or module is changed to fix them. This is most cost effective when considering the cost of the parts and labour. They only have to re-install the new board and check its calibration. When sending the phone for service, you must send the handset, power supply, and base unit. This way they can check it as a complete system. -- Greetings, Jerry Greenberg GLG Technologies GLG ============================================== WebPage http://www.zoom-one.com Electronics http://www.zoom-one.com/electron.htm Instruments http://www.zoom-one.com/glgtech.htm ============================================== "C Yeung" wrote in message ... Hi, I have a Siemens Gigaset 2415 cordless phone. It seems that after I talked on the phone for about 10-15 minutes, the other side could no longer hear me while I could still hear it clearly. If I switched to another phone, everything worked fine. If I switched back to the 2415 (2400) handset, it worked for a short time. The batteries are all fully charged. Just wondering if anyone knows what could be the problem! Thank you and best regards! Cliff. |
#4
|
|||
|
|||
Problem with Siemens Gigaset 2415
Duhh...you swapped out NiCads for NiMhs? Whenever something gives out,
always reverse your last step.... Previous discussions in this ng will point out the obvious flaws of this action. Use Google Groups to access several lengthy threads on the topic. Hopefully you haven't done any permanent damage; but doubtless the problem is related to the battery swap. jak "C Yeung" wrote in message ... Thanks! I suspected it as well since my wife was complaining about the batteries were getting hot after a while. I had changed them to NiMh. I will switch it to NiCd to see if it will help. If it has no improvement, I might as well get a new handset since it will cost me less to buy a new one than to send it to repair. Best regards! Cliff. "Jerry G." wrote: A component(s) have become thermo sensitive in the transmit section, or in the audio preamp section in the handset, or in the receive processing section in the base. The fault must be isolated. Most likely the fault is in the handset. Because of the way you are describing the fault, I doubt it is a cold solder connection. These units use high density LSI technology with multi layer boards. I doubt very much that you are even the corner service shop and even most large service centres can service this phone at the component level. You will have to send it to the authorized service centre for Siemens phones. If you consult the instruction manual, or call Siemens directly, they can advise you of the closest service rep to you. Most of the time, when these phones are sent for service, the complete circuit board or module is changed to fix them. This is most cost effective when considering the cost of the parts and labour. They only have to re-install the new board and check its calibration. When sending the phone for service, you must send the handset, power supply, and base unit. This way they can check it as a complete system. -- Greetings, Jerry Greenberg GLG Technologies GLG ============================================== WebPage http://www.zoom-one.com Electronics http://www.zoom-one.com/electron.htm Instruments http://www.zoom-one.com/glgtech.htm ============================================== "C Yeung" wrote in message ... Hi, I have a Siemens Gigaset 2415 cordless phone. It seems that after I talked on the phone for about 10-15 minutes, the other side could no longer hear me while I could still hear it clearly. If I switched to another phone, everything worked fine. If I switched back to the 2415 (2400) handset, it worked for a short time. The batteries are all fully charged. Just wondering if anyone knows what could be the problem! Thank you and best regards! Cliff. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Quick Change TP problem | Metalworking | |||
recent problem with Woodwork-L | Woodworking | |||
jointer problem | Woodworking | |||
Problem with JET Supersaw problem | Woodworking | |||
Sears air compressor starting problem | Woodworking |