Default Unusual Marshall amp fault

Considering all those personal names of testers/inspectors labelled inside.
a 1962 from 2003. A history of blowing fuses then would work for months then
blowing again. Is there a name for them , the little bits of wire of
cropped-off component leads. Anyway under the tremolo valve base , probably
sort of spot welded just the solder blob end , to one of the tags. A 5mm
long piece of cropped off lead from a 1W resistor or similar. It could swing
across, as only vaguely atached, and short the tags between a cathode and
anode. I assume it was loose somewhere inside the amp and then bounced into
just the wrong spot and current passing was just enough to just "solder" in
place on the first shorting excursion


  #2   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 379
Default Unusual Marshall amp fault

Considering all those personal names of testers/inspectors labelled inside.
a 1962 from 2003. A history of blowing fuses then would work for months then
blowing again. Is there a name for them , the little bits of wire of
cropped-off component leads. Anyway under the tremolo valve base , probably
sort of spot welded just the solder blob end , to one of the tags. A 5mm
long piece of cropped off lead from a 1W resistor or similar. It could swing
across, as only vaguely atached, and short the tags between a cathode and
anode. I assume it was loose somewhere inside the amp and then bounced into
just the wrong spot and current passing was just enough to just "solder" in
place on the first shorting excursion


Heh... good catch!

I once had to debug a NAD stereo receiver I'd bought, used... bad
crackling and popping on occasion, especially when tapped or banged.
Like a lot of Japanese kit from a couple of decades ago, it had quite
a few through-hold resistors in a "vertical" mounting position. Two
had leaned, or been bend over just enough that their flying upper
leads could make contact... POP!

--
Dave Platt AE6EO
Friends of Jade Warrior home page: http://www.radagast.org/jade-warrior
I do _not_ wish to receive unsolicited commercial email, and I will
boycott any company which has the gall to send me such ads!
  #3   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 2,001
Default Unusual Marshall amp fault

I've seen those waste ends many times although can't recall having to find
them as a result of a fault.

You're quite the detective, Nigel.

There were many boards where it was apparent that as part of the board
processing, it had been placed in some sort of fixture that would pass along
a belt sander-sort of arrangement to make all of the protruding leads a
uniform length.

The scratches of the abrasive were visible, and burrs formed on all the
leads were in the same direction.

I'd aways remove those waste tails/ends whenever I found them.. as some were
long enough to reach other solder pads, and frequently were over, but not in
good contact with adjacent pads.

--
Cheers,
WB
..............


"N_Cook" wrote in message
...
Considering all those personal names of testers/inspectors labelled
inside.
a 1962 from 2003. A history of blowing fuses then would work for months
then
blowing again. Is there a name for them , the little bits of wire of
cropped-off component leads. Anyway under the tremolo valve base ,
probably
sort of spot welded just the solder blob end , to one of the tags. A 5mm
long piece of cropped off lead from a 1W resistor or similar. It could
swing
across, as only vaguely atached, and short the tags between a cathode and
anode. I assume it was loose somewhere inside the amp and then bounced
into
just the wrong spot and current passing was just enough to just "solder"
in
place on the first shorting excursion



  #4   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 2,001
Default Unusual Marshall amp fault

Many of the old small transistor radios and similar portable gear from Japan
often had lengths of clear tubing on all the long leads for that 'vertical'
method of assembly.
Standing those axial-lead components on end was the early method of making
portable gear very compact.

I remember a radio which was only about 1-1/2" square and about 3/4" thick..
thin perforated aluminum speaker grille covering the front, and knobs on the
side.. much more compact than any other radio at the time, 1963 maybe.

--
Cheers,
WB
..............


"Dave Platt" wrote in message
...

Heh... good catch!

I once had to debug a NAD stereo receiver I'd bought, used... bad
crackling and popping on occasion, especially when tapped or banged.
Like a lot of Japanese kit from a couple of decades ago, it had quite
a few through-hold resistors in a "vertical" mounting position. Two
had leaned, or been bend over just enough that their flying upper
leads could make contact... POP!

--
Dave Platt AE6EO
Friends of Jade Warrior home page: http://www.radagast.org/jade-warrior
I do _not_ wish to receive unsolicited commercial email, and I will
boycott any company which has the gall to send me such ads!


  #5   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 5,247
Default Unusual Marshall amp fault

Wild_Bill wrote in message
...
I've seen those waste ends many times although can't recall having to find
them as a result of a fault.

You're quite the detective, Nigel.

There were many boards where it was apparent that as part of the board
processing, it had been placed in some sort of fixture that would pass

along
a belt sander-sort of arrangement to make all of the protruding leads a
uniform length.

The scratches of the abrasive were visible, and burrs formed on all the
leads were in the same direction.

I'd aways remove those waste tails/ends whenever I found them.. as some

were
long enough to reach other solder pads, and frequently were over, but not

in
good contact with adjacent pads.

--
Cheers,
WB
.............


"N_Cook" wrote in message
...
Considering all those personal names of testers/inspectors labelled
inside.
a 1962 from 2003. A history of blowing fuses then would work for months
then
blowing again. Is there a name for them , the little bits of wire of
cropped-off component leads. Anyway under the tremolo valve base ,
probably
sort of spot welded just the solder blob end , to one of the tags. A 5mm
long piece of cropped off lead from a 1W resistor or similar. It could
swing
across, as only vaguely atached, and short the tags between a cathode

and
anode. I assume it was loose somewhere inside the amp and then bounced
into
just the wrong spot and current passing was just enough to just "solder"
in
place on the first shorting excursion





Not really detective work. My repair methodology starts (after initial
powered up assessment if appropriate, then dismantling) with a full viewing
under a x5 illuminated inspection lamp+ bulbous lens. Noting unusual device
types, large R values if no schematic, state of solder joints, insulation,
discoloured areas etc. I just saw what initially looked like a non-cropped
off wiring-end ,through the valve base tag, ending too close to a pin 1 to
pin 7, bare cross-coupling wire. Up to then I was thinking mains transformer
interwinding fault.




  #6   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 29
Default Unusual Marshall amp fault

On Sat, 03 Dec 2011 13:17:22 +0000, N_Cook wrote:



Not really detective work. My repair methodology starts (after initial
powered up assessment if appropriate, then dismantling) with a full
viewing under a x5 illuminated inspection lamp+ bulbous lens. Noting
unusual device types, large R values if no schematic, state of solder
joints, insulation, discoloured areas etc. I just saw what initially
looked like a non-cropped off wiring-end ,through the valve base tag,
ending too close to a pin 1 to pin 7, bare cross-coupling wire. Up to
then I was thinking mains transformer interwinding fault.


Physical inspection is an important part of the diagnostic process. Good
eye.
  #7   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 314
Default Unusual Marshall amp fault

On Dec 4, 8:34*am, Wond wrote:
On Sat, 03 Dec 2011 13:17:22 +0000, N_Cook wrote:

Not really detective work. My repair methodology starts (after initial
powered up assessment if appropriate, then dismantling) *with a full
viewing under a x5 illuminated inspection lamp+ bulbous lens. Noting
unusual device types, large R values if no schematic, state of solder
joints, insulation, discoloured areas etc. I just saw what initially
looked like a non-cropped off wiring-end ,through the valve base tag,
ending too close to a pin 1 to pin 7, bare cross-coupling wire. Up to
then I was thinking mains transformer interwinding fault.


Physical inspection is an important part of the diagnostic process. Good
eye.


In my youth I impressed the hell out of one of my dad's friends, just
because I spotted a break in a pcb trace in his broken transistor
radio. ("Let spam take a look at it. He knows all about electronics.")
A second with the soldering iron set it right.
  #8   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 1,910
Default Unusual Marshall amp fault

Wond wrote:
On Sat, 03 Dec 2011 13:17:22 +0000, N_Cook wrote:



Not really detective work. My repair methodology starts (after initial
powered up assessment if appropriate, then dismantling) with a full
viewing under a x5 illuminated inspection lamp+ bulbous lens. Noting
unusual device types, large R values if no schematic, state of solder
joints, insulation, discoloured areas etc. I just saw what initially
looked like a non-cropped off wiring-end ,through the valve base tag,
ending too close to a pin 1 to pin 7, bare cross-coupling wire. Up to
then I was thinking mains transformer interwinding fault.


Physical inspection is an important part of the diagnostic process. Good
eye.


I always do a shake test, even with new computers to check for fallen out
screws, coins or other junk.


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Unusual keyboard fault Gareth Magennis Electronics Repair 3 December 8th 11 10:18 AM
Marshall JVM 410, 2006, PbF N_Cook Electronics Repair 5 July 19th 11 05:17 PM
Marshall amps , stock fault ? c2003 N_Cook Electronics Repair 0 March 23rd 10 09:52 AM
Marshall AVT50 N_Cook Electronics Repair 1 December 15th 08 09:29 PM
Marshall G80R CD redamp75 Electronics Repair 1 February 3rd 05 04:11 AM


All times are GMT +1. The time now is 04:47 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"