Luxmn L-10 service manual or transformer details
 
Hi,
I need specs for the Luxman L-10 transformer since i have to get it
rewound. The rewinder said it'd be easier for him if i were to provide
him with voltage and current specs for each winding.The right channel
transformer has more windings than the left does.Vcc for the preamp
stages is also generated in the right channel transformer while the
left simply powers the left channel power amp. Any one with a
schematic or details please?
Jango

William Sommerwerck September 2nd 09 12:40 PM

Luxman L-10 service manual or transformer details
 
This company

http://www.onahighernote.com/about

is the American distributor. Perhaps they can ask Japan for information.



Andras September 28th 09 05:03 PM

Luxmn L-10 service manual or transformer details
 
On szept. 2, 12:24, jango2 wrote:
Hi,
I need specs for the Luxman L-10 transformer since i have to get it
rewound. The rewinder said it'd be easier for him if i were to provide
him with voltage and current specs for each winding.The right channel
transformer has more windings than the left does.Vcc for the preamp
stages is also generated in the right channel transformer while the
left simply powers the left channel power amp. Any one with a
schematic or details please?
Jango



Ross Herbert September 29th 09 02:54 AM

Luxmn L-10 service manual or transformer details
 
On Wed, 2 Sep 2009 03:24:33 -0700 (PDT), jango2
wrote:

:Hi,
:I need specs for the Luxman L-10 transformer since i have to get it
:rewound. The rewinder said it'd be easier for him if i were to provide
:him with voltage and current specs for each winding.The right channel
:transformer has more windings than the left does.Vcc for the preamp
:stages is also generated in the right channel transformer while the
:left simply powers the left channel power amp. Any one with a
:schematic or details please?
:Jango

And what makes you think Luxman are going to make details of their own
proprietary designs freely available to the public or any service organisation?

Luxman - and most audio eqpt manufacturers - design their power transformers
specifically for the model concerned. You won't find an off-the-shelf
replacement anywhere and you won't find the winding details unless you
physically strip one down and count the turns. That's a lot of hard work and
nobody in their right mind will usually feel it is worthwhile. If it fails you
simply have to buy a new one from them...

Having said that you might find that the reason for the transformer failure is
the thermal fuse they generally include in the primary winding. In some
transformers it is possible to access this fuse by breaking away some of the
webbing on the winding bobbin and removing the fuse and then by-passing it. I
managed to do this recently when faced with the same problem.

William Sommerwerck September 29th 09 12:50 PM

Luxmn L-10 service manual or transformer details
 
And what makes you think Luxman are going to make
details of their own proprietary designs freely available
to the public or any service organisation?


If the product is no longer available, why shouldn't Lux provide the
information? Besides, anyone with the time and patience cold unwind the
transformer.

Lux was originally a transformer company, but the way.



Ross Herbert September 30th 09 02:40 AM

Luxmn L-10 service manual or transformer details
 
On Tue, 29 Sep 2009 04:50:38 -0700, "William Sommerwerck"
wrote:

: And what makes you think Luxman are going to make
: details of their own proprietary designs freely available
: to the public or any service organisation?
:
:If the product is no longer available, why shouldn't Lux provide the
:information? Besides, anyone with the time and patience cold unwind the
:transformer.
:
:Lux was originally a transformer company, but the way.
:


I don't know why they won't,,, but they just won't.

Do you know of any audio equipment manufacturer (even though the item might be
obsolete) who is prepared to provide technical details of how to wind one of
their transformers?

I also said in my post that the option to unwind and count the turns is
available to those with the urge.

William Sommerwerck September 30th 09 01:11 PM

Luxmn L-10 service manual or transformer details
 
I don't know why [Lux] won't, but they just won't.

Do you know of any audio equipment manufacturer (even
though the item might be obsolete) who is prepared to
provide technical details of how to wind one of their
transformers?


In fairness, I don't. Lux might not even know.