Have a 27" Proscan that works fine once you get it to come on, but
intermittently will not start up. When it won't start there is no 143 volts
standby voltage. There is raw 150 volts, actually more like 160 volts.
Haven't yet found any shorted or open components in regulator circuit.
Any tips on what is the most common component failure with these symptoms.
Thanks.


  #2   Report Post  
Posted to sci.electronics.repair
AJ AJ is offline
external usenet poster
 
Posts: 107
Default CTC 169 Chassis

Replace the 15 Volt rectifier diode and check the electrolytic caps in the
regulator circuit.
"JAG" wrote in message
...
Have a 27" Proscan that works fine once you get it to come on, but
intermittently will not start up. When it won't start there is no 143
volts standby voltage. There is raw 150 volts, actually more like 160
volts. Haven't yet found any shorted or open components in regulator
circuit.
Any tips on what is the most common component failure with these symptoms.
Thanks.


  #3   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 3
Default CTC 169 Chassis

Been out ot touch since email has been down, but think I have found trouble.
Turned out to be 2.2mfd cap in regulator circuit, but thanks anyway for
response. Your suggestion would have been right on. Thanks.
"AJ" wrote in message
. ..
Replace the 15 Volt rectifier diode and check the electrolytic caps in the
regulator circuit.
"JAG" wrote in message
...
Have a 27" Proscan that works fine once you get it to come on, but
intermittently will not start up. When it won't start there is no 143
volts standby voltage. There is raw 150 volts, actually more like 160
volts. Haven't yet found any shorted or open components in regulator
circuit.
Any tips on what is the most common component failure with these
symptoms. Thanks.




Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
11ak30 chassis b Electronics Repair 8 October 2nd 06 08:13 AM
RCA ptk 178 chassis [email protected] Electronics Repair 0 August 2nd 06 09:23 PM
32" Sony tv model:KV-32S22,chassis:SCC-K97D-A,chassis:AA-2D [email protected] Electronics Repair 2 February 8th 06 12:55 PM
CTC146E Chassis CompNurse Electronics Repair 3 October 12th 05 07:16 PM
chassis help dynodan Electronics Repair 0 November 10th 03 07:50 PM


All times are GMT +1. The time now is 04:31 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"