20" Daewoo tv/vcr combo model:DVN-20F6N,chassis:CN-140
20" Daewoo tv/vcr combo model:DVN-20F6N (same as DVT-21F2PA & White
Westinghouse model:WTV11911),chassis:CN-140,year:Oct 1998,no power (no 5v standby).This unit Ib01=STRS507 as the SMPS power supply switcher,the problem is around there as there are no secondary voltages out of the SMPS xfmr. I tested the components with my Fluke DMM series II model:29 but they tested fine and I am on slow dial up internet so cannot download the service manual below: http://www.e-daewoo.com/service_new/...140N-010_1.pdf Anyone have any common repair tips?.Thanks in advance. Sidney Dartmouth,Nova Scotia Canada Free service manual downloads: http://www.schematicsforfree.com http://www.schematicsforfree.mattsoft.net http://schematicsforfree.mattsoft.net http://schforfree.seedhost.com http://www.epanorama.net/schematicsforfree then click on "click here to see the files" followed by "video" followed by "products". |
All times are GMT +1. The time now is 06:25 PM. |
Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.