can a three phase motor work on single phase?
|
can a three phase motor work on single phase?
Hello, 3T39!
You wrote to All on Fri, 29 Sep 2006 12:12:47 +0100: T Is there any way to make a three phase concrete breaker work on 240V T single phase UK mains? here is a photo of the label attached to the T machine. Many thanks OOoops forgot the link http://i10.tinypic.com/2zsql54.jpg With best regards, 3T39. E-mail: |
can a three phase motor work on single phase?
You have worse problems than the three phase requirement. This unit
runs on 200V and 400Hz. You need to find a converter that converts from single phase 230V 50Hz to three phase 200V 400 Hz. |
can a three phase motor work on single phase?
Thomas Tornblom wrote in :
This unit runs on 200V and 400Hz. ????? Where in the world is the power 200V 400Hz? |
can a three phase motor work on single phase?
Jim Land (NO SPAM) wrote:
Thomas Tornblom wrote in : This unit runs on 200V and 400Hz. ????? Where in the world is the power 200V 400Hz? 400Hz usually means aircraft NT |
can a three phase motor work on single phase?
Jim Land wrote:
Thomas Tornblom wrote in : This unit runs on 200V and 400Hz. ????? Where in the world is the power 200V 400Hz? In an airplane? Or an army facility? I have worked in some of them,listening to the 3rd harmonic tone going on all day, a radar facility, and air command centre. |
can a three phase motor work on single phase?
|
can a three phase motor work on single phase?
Thomas Tornblom wrote:
You have worse problems than the three phase requirement. This unit runs on 200V and 400Hz. You need to find a converter that converts from single phase 230V 50Hz to three phase 200V 400 Hz. Just replace the motor, you're not likely to find a VFD that will go up to 400Hz. |
can a three phase motor work on single phase?
"3T39" wrote in message ... Hello, 3T39! You wrote to All on Fri, 29 Sep 2006 12:12:47 +0100: T Is there any way to make a three phase concrete breaker work on 240V T single phase UK mains? here is a photo of the label attached to the T machine. Many thanks OOoops forgot the link http://i10.tinypic.com/2zsql54.jpg No problemo. Get one of these: http://www.airport-technology.com/co...r_system1.html |
can a three phase motor work on single phase?
Some shops used 400Hz power internally for a lot of tools. Probably
allowed them to be lighter, less iron core needed in motors AFAIK. |
can a three phase motor work on single phase?
"Thomas Tornblom" wrote in message ... Some shops used 400Hz power internally for a lot of tools. Probably allowed them to be lighter, less iron core needed in motors AFAIK. Yes, but also the employees couldn't steal them and use them at home! |