Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

 
 
LinkBack Thread Tools Search this Thread Display Modes
Prev Previous Post   Next Post Next
  #1   Report Post  
Posted to sci.electronics.repair
 
Posts: n/a
Default Urgent help req !! - guitar amplifier channel switch fault.

Hi,

I've done a stupid thing with my new guitar amp, and sent 9v DC where
it shouldn't go, and now it won't change channels.

Please can someone help ? I've uploaded a schematic (866kb) he
http://homepage.ntlworld.com/anengineer/vc15.pdf

Scroll to the bottom page (page 3) (for some reason they included an
earlier, incomplete revision on page 2 !), and the relevant section is
grid ref A3 to A6.

I connected a badly wired external switch box to the 'Remote' jack in
grid A3, and sent 9v DC up all three connectors - sleeve, ring & tip.

The normal operation of the amp is that it has a 'clean' channel and a
'distortion' channel, switched by either the latching push-switch on
the amp ('SW2A' - grid A4), or by a remote switch via the jack in grid
A3. Either switch takes the line to ground to activate the relay (grid
A5/6), which switches the channel, and illuminates LED1 (grid A6).

Currently, LED1 is permanently ON and the amp is stuck on the
distortion channel. Neither SW2A nor an external switch has any effect
now, and there is no 'click' from the relay.

The 'Remote' jack also allows switching on/off of the built-in reverb
(short ring to sleeve [ground] for OFF) - but thankfully this seems to
still be working ok. - However, shorting tip and ring on the 'Remote'
jack also switches the reverb off - suggesting that the 'tip' line is
permanently shorted to ground.

Looking at the schematic, my guess is that D2 has gone short-circuit -
but then, that is an amateur's guess !

Please could someone suggest what I should test / replace ?

Many, many thanks to anyone who can advise.

Cheers,

Kev.

 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
The Woodworking Channel gary in virginia Woodworking 19 April 16th 06 07:48 AM
Trip switch keeps going - electircal fault [email protected] UK diy 2 March 6th 06 02:28 AM
Anyone, Advice please - another electrical light switch puzzle thingŠ wilma harrington Home Repair 11 February 19th 06 02:19 PM
Incorrectly wired a three way switch? miamicuse Home Repair 8 November 9th 05 02:43 AM
how to rewire bathroom pull switch to regular light switch Nick UK diy 20 January 20th 04 07:57 PM