CTC 203 common failure.
When repairing these chassis, it's been my understanding
that if you "catch" these units before the horizontal drive coil gets bad, & repair it, it won't fail. None of the sets I have done this repair on (with other issues), have ever come back, with that problem, at least over my 60 day warranty. Thoughts, Rono. |
That is a prime failure in these sets, which in turn can cause failure of
the horiz output device. I have also seen quite a few 203 chassis with LOPT failures also, not specifically related to the specific coil in the base circuitry of the horiz output device. I.E L14401 & similar. BTW this coil design had been used in many previous Thomsom chassis with ocassional problems being generated but the 203 seems to be a real bugger with them. "Rono" wrote in message ... When repairing these chassis, it's been my understanding that if you "catch" these units before the horizontal drive coil gets bad, & repair it, it won't fail. None of the sets I have done this repair on (with other issues), have ever come back, with that problem, at least over my 60 day warranty. Thoughts, Rono. |
All times are GMT +1. The time now is 08:52 PM. |
Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004 - 2014 DIYbanter