DIYbanter

DIYbanter (https://www.diybanter.com/)
-   Electronics Repair (https://www.diybanter.com/electronics-repair/)
-   -   Lexicon MRC schematics (https://www.diybanter.com/electronics-repair/111240-lexicon-mrc-schematics.html)

Bob Urz July 1st 05 02:52 PM

Lexicon MRC schematics
 
Anyone got a schematic on a Lexicon MRC Midi controller?
I have got two dead ones i have been trying to get going for
customers for awhile. Kind of hard with no prints. Essentially
a one board computer with Z80, 4 rom, static ram, uart,analog
input chip, and display controller.

Unit #1 will go though self test until it get to the Duart test
and them the display goes to gibberish and unit locks up.
Subbed the CPU, RAM and Duart from another working unit and all
the symptoms stayed the same.

Unit #2 comes up with display solid, no activity. Swapped
CPU,RAM,DUART and still the same. Now, this unit has the
CPU reset line staying low. I think this is related to the
problem but need to find the circuit that controls the CPU
reset on power up. I am hunting down some generic Z80 circuits
for a guide.

Both have the EL panels out, but that's a moot point with no
brain activity........

Bob

----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==----
http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups
----= East and West-Coast Server Farms - Total Privacy via Encryption =----

BOB URZ July 1st 05 06:00 PM



Bob Urz wrote:

Anyone got a schematic on a Lexicon MRC Midi controller?
I have got two dead ones i have been trying to get going for
customers for awhile. Kind of hard with no prints. Essentially
a one board computer with Z80, 4 rom, static ram, uart,analog
input chip, and display controller.

Unit #1 will go though self test until it get to the Duart test
and them the display goes to gibberish and unit locks up.
Subbed the CPU, RAM and Duart from another working unit and all
the symptoms stayed the same.


This one will have to wait since i robbed the max 690 out of it.
But i am still looking for theories. Since it goes through self test
fine until it hits the DUART, its got to be some problem there.
The Duart is socketed, and i swapped it with a good one an
there is no change. So it cannot be the chip. But, i could be some
issue with the addressing of the chip. Maybe an address decoder?
If i had a Z80 Micro emulator to hook to it i could easily track it down. But that's
not a tool i have laying around




Unit #2 comes up with display solid, no activity. Swapped
CPU,RAM,DUART and still the same. Now, this unit has the
CPU reset line staying low. I think this is related to the
problem but need to find the circuit that controls the CPU
reset on power up. I am hunting down some generic Z80 circuits
for a guide.


Well, i got unit #2 back on line. Downloaded some generic z80
block diagrams. I figured out that the reset pin on the Z80 has some sort of drive.
Traced it down to a MAX690 chip. I compared voltages
to the good and bad unit and all was the same EXCEPT the reset pin.
So i figured this ruled out a power or low battery problem.
Swapped the chips between the units and it brought the unit back to life.

I am also investigating some LED fiber optic replacements for the EL panel on the unit.

Bob




Both have the EL panels out, but that's a moot point with no
brain activity........

Bob

----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==----
http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups
----= East and West-Coast Server Farms - Total Privacy via Encryption =----



----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==----
http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups
----= East and West-Coast Server Farms - Total Privacy via Encryption =----

Gareth Magennis July 4th 05 03:33 PM

This one will have to wait since i robbed the max 690 out of it.
But i am still looking for theories. Since it goes through self test
fine until it hits the DUART, its got to be some problem there.
The Duart is socketed, and i swapped it with a good one an
there is no change. So it cannot be the chip. But, i could be some
issue with the addressing of the chip. Maybe an address decoder?
If i had a Z80 Micro emulator to hook to it i could easily track it down.
But that's
not a tool i have laying around



In my experience, if you have a working one to compare it with you're
laughing. Well, maybe a slight chuckle. Scope all the pins of the working
UART and you may be able to see roughly what kind of signals should be there
and those that are missing or corrupted on the duff one.

Or you could try removing both UARTS and then compare signals - maybe a more
obvious boot up difference/failiure mode may become apparent. (You would
have to constantly reset each machine to see these boot up procedures
working)

Good luck,

Gareth.



Bob Urz July 4th 05 04:24 PM



Gareth Magennis wrote:
This one will have to wait since i robbed the max 690 out of it.
But i am still looking for theories. Since it goes through self test
fine until it hits the DUART, its got to be some problem there.
The Duart is socketed, and i swapped it with a good one an
there is no change. So it cannot be the chip. But, i could be some
issue with the addressing of the chip. Maybe an address decoder?
If i had a Z80 Micro emulator to hook to it i could easily track it down.
But that's
not a tool i have laying around




In my experience, if you have a working one to compare it with you're
laughing.


That's how i confirmed the problem with the reset pin driver chip on the
other unit. All was the same except one pin, the reset pin.


The one that goes into la la land i can make some assumptions.
I swapped CPU, UART, RAM, ROM from a working unit and the
symptoms were the same. And the swapped chips worked in the
working unit. SO, i would assume its NOT a problem with any of
the socketed chips. The unit will go into self test and gets up
to the DUART test before it goes south. SO i would assume the
basic data and address lines are intact. Power seems to be OK,
but further tests are always in order.

I think it some sort of chip addressing issue. Since i have no print
and its NLA from Lexicon, i will have to wait until i can trace
the chips down and draw one out. The one unit that did this i
modified with the V4 roms, but all seems to be OK with that.

Bob




Well, maybe a slight chuckle. Scope all the pins of the working
UART and you may be able to see roughly what kind of signals should be there
and those that are missing or corrupted on the duff one.

Or you could try removing both UARTS and then compare signals - maybe a more
obvious boot up difference/failiure mode may become apparent. (You would
have to constantly reset each machine to see these boot up procedures
working)

Good luck,

Gareth.



----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==----
http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups
----= East and West-Coast Server Farms - Total Privacy via Encryption =----

Gareth Magennis July 5th 05 10:49 AM

I think it some sort of chip addressing issue.


Have you checked the clock into the UART?


Gareth.