Magnavox/Phillips MS3650C129 lightning
I need your help on this one.
Magnavox/Phillips MS3650C129 Chassis #36M800 7603 (other numbers 6560-BYV29X) TV dead after lightning. Line fuse OK. Diode (board number) 6560 shorted. That's all I have found so far. Replaced the diode with ECG598. Pushed the power button and heard the click of death. Replacement diode again shorted. I called the number found in Sams index for Phillips and was sternly informed by a recorded voice to go to "thepartsstore.com". I didn't have any luck there. You need a password, which is only issued with an account number. Not desiring to submit financials to open an account for this one job, I quit looking for help from the manfacturer. I would like to purchase a drawing and proceed from there. Is there a way around this roadblock--and would anyone have a suggestion on probable lightning damage patterns on this chassis? Thanks David, on the Illinois prairie. (I sold a new TV to the customer, so this one is mine and is not a rush job.) |
|
Bill S wrote: 6560 is the main supply (140V) rectifier. Check 7460 HOT and other stuff on the main supply. Schematic is available only on the Philips service CD, unless you can sweet-talk someone into sending it to their printer. Bill--thanks for the pointers. I will talk very sweetly to anyone who is out there! David, on the Illinois prairie. |