Zenith 35" T.V.!!
M # Z35X21D, rebuilt PWM power supply:
Replaced CX3416 100uf, CX 3413 22uf, CX3424 2200 uf, both regulators, unit works fine in every way, but regulator heatsink get very hot. Touch it for 3-4 seconds...ouch. But the unit runs all day, just afraid it will overheat & "blow" again. Did I miss anything to cause overheating? Horizontal output is cool enough. Rono. |
Check the load circuits for those specific regulators, may have something
causing increase current demand. "Rono" wrote in message ... M # Z35X21D, rebuilt PWM power supply: Replaced CX3416 100uf, CX 3413 22uf, CX3424 2200 uf, both regulators, unit works fine in every way, but regulator heatsink get very hot. Touch it for 3-4 seconds...ouch. But the unit runs all day, just afraid it will overheat & "blow" again. Did I miss anything to cause overheating? Horizontal output is cool enough. Rono. |
If it's not already home, send it home. They do run very hot. That's why this repair is rather common. David, on the Illinois prairie. |
All times are GMT +1. The time now is 07:40 PM. |
Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.