Electronic Schematics (alt.binaries.schematics.electronic) A place to show and share your electronics schematic drawings.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to alt.binaries.schematics.electronic
external usenet poster
 
Posts: 488
Default Precise voltages from imprecise parts..

Target: shunt regulator, 300V 0.1% from 20uA to 500uA.

Used LM285, J175, and trimmed divider for 25V 0.1% regulator.
Used 1% resistors, added one calculated fixed trimming resistor to
get 25.000V for 0.1% result at 20uA.
Made twelve of these, in series to achieve 300V for presumed 0.1%
precision.

Well, the results are OK, but not quite "right".
Firstly, it is high by 0.3%.
Then there is a seeming discrepancy: a Tektronix 7CT1N curve tracer
on six of the 25V trimmed regulators reads 150.24V (a bit above the
0.1%), but minimum current is 40uA (??).
Direct measurement of the twelve is 300.9V from 30uA to 470uA which
is high by 0.3%.

I do not have an adjustable supply to try 20uA "zener" current so
must assume the current displayed on the 7CT1N is in error, but that is
a factor of two and not a mere 1% or so.

Any idea as to why the error is so high (0.3%) and why the apparent
minimum operating current is way above the individually measured 20uA
used for setting each 25V regulator?



Attached Images
File Type: bmp 25V500.bmp (866.3 KB, 86 views)
Attached Files
File Type: txt 300V.TXT (930 Bytes, 90 views)
  #2   Report Post  
Posted to alt.binaries.schematics.electronic
external usenet poster
 
Posts: 488
Default Precise voltages from imprecise parts..UPDATE

Robert Baer wrote:
Target: shunt regulator, 300V 0.1% from 20uA to 500uA.

Used LM285, J175, and trimmed divider for 25V 0.1% regulator.
Used 1% resistors, added one calculated fixed trimming resistor to get
25.000V for 0.1% result at 20uA.
Made twelve of these, in series to achieve 300V for presumed 0.1%
precision.

Well, the results are OK, but not quite "right".
Firstly, it is high by 0.3%.
Then there is a seeming discrepancy: a Tektronix 7CT1N curve tracer on
six of the 25V trimmed regulators reads 150.24V (a bit above the 0.1%),
but minimum current is 40uA (??).

* Basically resolves with more careful measurement using no added metering.

Direct measurement of the twelve is 300.9V from 30uA to 470uA which is
high by 0.3%.

I do not have an adjustable supply to try 20uA "zener" current so must
assume the current displayed on the 7CT1N is in error, but that is a
factor of two and not a mere 1% or so.

* Roughly resolved, by separate, added voltage measurements with a
forgotten 200K/V analog meter, at currents near the "knee".

Any idea as to why the error is so high (0.3%)?




Attached Images
File Type: bmp 25V500.bmp (866.3 KB, 93 views)
Attached Files
File Type: txt 300V.TXT (988 Bytes, 81 views)
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
about precise cutting on stainless tubing jc Metalworking 3 March 30th 10 02:42 PM
Precise Long Cuts? Adam[_2_] Woodworking 19 November 26th 07 08:14 PM
Precise grinder Dick Metalworking 8 October 26th 05 01:18 PM
precise orientation fastener ideas steve Metalworking 22 June 23rd 05 08:16 PM
Less precise machines building more precise machines B.B. Metalworking 11 September 18th 04 08:40 PM


All times are GMT +1. The time now is 01:08 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us