View Single Post
  #19   Report Post  
Posted to rec.woodworking
Scott Lurndal Scott Lurndal is offline
external usenet poster
 
Posts: 2,377
Default 4 foot LED "shop" lighting

whit3rd writes:
On Thursday, October 15, 2020 at 2:13:48 PM UTC-7, wrote:
I just use 4 foot fluorescent lights in my shop area. I have 37 of the two bulb 4 foot fixtures in the basement. Once in a great while the fluorescent bulbs die. But its rare. And the bulbs cost $1 each or something like that.


Yep, fluorescent is still a winner on parts/availability/maturity, and was never far
behind LED in power consumption.


I would argue that a 50% reduction in power consumption between fluorescent and
LED does indicate that fluorescent is "far behind LED in power consumption".


I suspect the various (low-voltage DC, high-voltage AC,
dimmable, not dimmable, flickering, flicker-free, etc.) LED options mean that one
can never re-lamp or re-power a fixture, if a lamp or power brick dies, you need... a new
fixture.


You can buy replacement LED tubes for standard fluorescent fixtures, the tubes
run on line voltage, so you simply rewire the fixture to bypass the ballast.

I've converted a dozen F96T12 two-bulb fixtures with LED tubes, which _are_
easily replaceable.

You can also get LED tubes that are drop-in replacement in standard
48" fixtures using the existing ballast.