On 12/05/2019 16:07, Prouvost wrote:
Adjust the pressure in the bladder & pressure switch if necessary
(1) Pressurize bladder to 28 psi
(2) Center large nut (3/8") adjusts the cut-in/cut-out 20-degree range
Â*Â* 1 clockwise rotation tightening the large spring adds 2-3 psi
Â*Â* Example values are 35-55 psi, 40-60 psi, 45-65 psi, and so on
(3) Side small nut adults the cut-out pressure only (widens the range)
Â*Â* 1 clockwise rotation = 2-3 psi
Â*Â* Example values are 35-55+2 psi, 40-60+2 psi, 45-65+2 psi, and so on
System overview videos
(1) [https://youtu.be/X4TZoFIsE2w]
(2) [https://youtu.be/CQayY5FTNKk]
Does his style of posting look familiar ...
--
Adrian C