View Single Post
  #3   Report Post  
Posted to sci.electronics.repair
Jon Elson Jon Elson is offline
external usenet poster
 
Posts: 1,384
Default VFD and line reactor

On Fri, 15 Mar 2019 10:09:03 -0700, etpm wrote:


Besides power factor correction does the line reactor do anything
else that might prevent any problems? Such as stopping any noise that
might interfere with and CNC machines that are wired into the same
circuit breaker panel?

Yes, I had a few pieces of computer-type gear that were affected by a VFD
on my CNC mill. I put a heavy-duty commercial line filter box on it, and
all the interference went away. This is an LC filter, not just a reactor.
I found a suitable filter in my junk.

Jon