Ok, a quick google search reveals that the CRT specific rejuvenators apply a high potential between the cathode and G1. The resulting arcing exposes some "fresh" cathode surface. I'd have to believe the area would be tiny and therefore the fix very temporary. Seems like it would also be prone to throwing cathode debris at the phosphor surface, aperture mask, or gun aperture. Ugh. But now I understand the ZAP reference.

I was familiar with the older method that used general purpose tube testers with CRT adapters. There was no such capability with those that I was aware of -- only raising the filament voltage to overheat the cathode and boil up the emitting surface. Seems like a better chance of lasting results, if the filament survives the process.

Funny because I owned a B&K 467 for a while, but I don't think I ever tried to use it for rejuvenation.