On Monday, October 10, 2016 at 9:55:49 AM UTC-4, Chris Jones wrote:

That could happen if the motor controller is very crude, but a good
motor controller would incorporate current limiting, and the current
limit should be set below the fuse blowing current.


Bluntly, I would be surprised if the motor controller is anything more than a primitive SCR speed control and a fuse as a last-resort. These go-buggies are just short of a racket, with a very few genuine exceptions. And a brush-type DC motor will pull current even when not turning right down to a dead-short when the voltage drops below what is necessary to turn the motor against the load - and THAT is what blows the fuse.

Peter Wieck