On Thu, 19 Nov 2015 08:25:33 -0800, DaveC Gave us:

Good point... The ends of the shrink shroud will have to be protected to
ensure that the oil does not get inside. Otherwise it will "hang
around" doing its worst!

Mike.


I will put RTV in the end of the shrink and apply heat. Shrink-n-seal. All
this will be well inside the multipin connector so will be clamped with
strain relief.

Thanks.



No. Do not do that. RTV detaches with a sneeze.

Use "lined" shrink tubing for the cable end dress..

A shorter piece, and when heated, it exudes a sealant internally.

One way to source it is to search for "HV heat shrink". It is usually
of the lined variety.