Your experience witg function generators
"Antonio I0JX"
Frequency measurement results:
- Just turned on. Frequency = 5.000 MHz Delta F = 0
- 15 minutes after. Delta F = -98 kHz (drift = 6.5 kHz per minute)
- 30 minutes after. Delta F = - 116 kHz (drift = 3.7 kHz per minute)
- 45 minutes after. Delta F = -132 kHz (drift = 2.9 kHz per minute)
- 60 minutes after. Delta F = -141 kHz (drift = 2.3 kHz per minute)
- 75 minutes after. Delta F = -147 kHz (drift = 2.0 kHz per minute)
Drift is too high for any practical use.
** A function generator is ** NOT ** an RF generator !!!
The drift you are seeing is completely normal - for a function generator.
Bloody stupid radio ham.