View Single Post
  #16   Report Post  
Posted to sci.electronics.repair
Phil Allison[_2_] Phil Allison[_2_] is offline
external usenet poster
 
Posts: 1,716
Default Your experience witg function generators


"Antonio I0JX"


Frequency measurement results:

- Just turned on. Frequency = 5.000 MHz Delta F = 0
- 15 minutes after. Delta F = -98 kHz (drift = 6.5 kHz per minute)
- 30 minutes after. Delta F = - 116 kHz (drift = 3.7 kHz per minute)
- 45 minutes after. Delta F = -132 kHz (drift = 2.9 kHz per minute)
- 60 minutes after. Delta F = -141 kHz (drift = 2.3 kHz per minute)
- 75 minutes after. Delta F = -147 kHz (drift = 2.0 kHz per minute)

Drift is too high for any practical use.



** A function generator is ** NOT ** an RF generator !!!

The drift you are seeing is completely normal - for a function generator.

Bloody stupid radio ham.