JIMMIE wrote:

On Feb 10, 11:38 am, Jeff Liebermann wrote:
On Fri, 10 Feb 2012 06:17:03 -0800 (PST), JIMMIE

wrote:
Jeff, I installed TVRO systems for several years and used a lot of F
connectors. Suprisingly the ones I found that worked best were the
ultra cheap ones that only took a pair of pliers to fasten These were
the ones with the separate crimp rings. Used with some good quality
heat shrink tubing this eliminated most of the problems you mention. I
dont know why these connectors went away, my only guess is that
someone wasn't making enough money on them.


Jimmie


Yech...

Please try this test. Insert such a crimp type F connector and cable
into some useless piece of equipment with a type F jack. Pull on the
cable hard. In my experience, it doesn't take much to make the cable
and connector part ways. Repeat with a screw on connector. Now,
repeat the experiment using a properly assembled compression type F
connector and cable. It takes considerably more brute force to break
the connection. I think the official minimum pull test is 55 lbs, but
I'm too lazy to Google for it now.

Hiding the workmanship under shrink tube is not very functional. It
will have little effect on the pull test.

Most of the cable leakage problems I've seen (and found) were due to
crimp type F connectors coming apart or badly crimped. That includes
both the hex shaped crimp, and ones held together with a crimped ring.

Bad:
http://www.fconnector.org/wp-content/uploads/2011/12/F-Connector2.jpg

Worse:
http://www.showmecables.com/images/catalog/product/F-connector-RG59.j...

Good:
http://images.lowes.com/product/converted/783250/783250926510lg.jpg

--
Jeff Liebermann
150 Felker St #D http://www.LearnByDestroying.com
Santa Cruz CA 95060http://802.11junk.com
Skype: JeffLiebermann AE6KS 831-336-255


Sorry Jeff but I never used my connectors to support my cables. You
may be right but completely irrelevant to me. To me F connector and
good connection shouldn't even be used in the same sentence. They are
what that are, cheap connectors at best that uses the center conductor
of the cable for a contact.



Then you would hate most microwave connectors lit SMA.


Now that is Yech. Heat shrink has nothing
to do with the pull test or hiding poor workmanship but it does help
keep corrosion down which is the biggest problem with F connectors.



You didn't need heat shrink on good 'F' connectors.

Ive never seen one pull apart except in the shoddiest of
installations. One of the best things I have found to insure you
maintain a good connection is to apply something like DeOxit to the
connectors when you assemble them. Best done while all the parts are
new.



Not needed, if you use flooded outdoor cable.


--
You can't have a sense of humor, if you have no sense.